Spatial resolved quantitation of chemical species in thin tissue sections by mass spectrometric methods has been constrained by the need for matrix-matched standards or other arduous calibration protocols and procedures to mitigate matrix effects (e.g., spatially varying ionization suppression). Reported here is the use of laser "cut and drop" sampling with a laser microdissection-liquid vortex capture electrospray ionization tandem mass spectrometry (LMD-LVC/ESI-MS/MS) system for online and absolute quantitation of propranolol in mouse brain, kidney, and liver thin tissue sections of mice administered with the drug at a 7.5 mg/kg dose, intravenously. In this procedure either 20 μm × 20 μm or 40 μm × 40 μm tissue microdissections were cut and dropped into the flowing solvent of the capture probe. During transport to the ESI source drug related material was completely extracted from the tissue into the solvent, which contained a known concentration of propranolol-d7 as an internal standard. This allowed absolute quantitation to be achieved with an external calibration curve generated from standards containing the same fixed concentration of propranolol-d7 and varied concentrations of propranolol. Average propranolol concentrations determined with the laser "cut and drop" sampling method closely agreed with concentration values obtained from 2.3 mm diameter tissue punches from serial sections that were extracted and quantified by HPLC/ESI-MS/MS measurements. In addition, the relative abundance of hydroxypropranolol glucuronide metabolites were recorded and found to be consistent with previous findings.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.6b01155DOI Listing

Publication Analysis

Top Keywords

absolute quantitation
12
thin tissue
12
tissue sections
12
μm μm
12
online absolute
8
quantitation propranolol
8
laser microdissection-liquid
8
microdissection-liquid vortex
8
laser "cut
8
"cut drop"
8

Similar Publications

Patterns of use of heated tobacco products: a comprehensive systematic review.

J Epidemiol

January 2025

Department of Medical Epidemiology, Istituto di Ricerche Farmacologiche Mario Negri IRCCS.

Introduction: Relative or absolute safety of heated tobacco products (HTP) remains unknown, while independent literature suggests that these products do not favour tobacco control. We conducted a comprehensive systematic review and meta-analysis to evaluate HTP usage patterns and the effect of HTP use on conventional tobacco smoking (use transitions).

Methods: We used Pubmed/MEDLINE, Embase and the Cochrane Library to identify all articles published up to February 2022 on HTP use.

View Article and Find Full Text PDF

Objective Applying carbon ion beams, which have high linear energy transfer and low scatter within the human body, to Spatially Fractionated Radiation Therapy (SFRT) could benefit the treatment of deep-seated or radioresistant tumors. This study aims to simulate the dose distributions of spatially fractionated beams (SFB) to accurately determine the delivered dose and model the cell survival rate following SFB irradiation. Approach Dose distributions of carbon ion beams are calculated using the Triple Gaussian Model.

View Article and Find Full Text PDF

Background: Computed tomography (CT)-derived low muscle mass is associated with adverse outcomes in critically ill patients. Muscle ultrasound is a promising strategy for quantitating muscle mass. We evaluated the association between baseline ultrasound rectus femoris cross-sectional area (RF-CSA) and intensive care unit (ICU) mortality.

View Article and Find Full Text PDF

Enhancing safety in CT-guided lung biopsies: correlation of MinIP imaging with pneumothorax risk prediction.

Insights Imaging

January 2025

Department of Diagnostic, Interventional and Paediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.

Objectives: This study aimed to evaluate whether minimum-intensity projection (MinIP) images could predict complications in CT-guided lung biopsies.

Methods: We retrospectively analyzed 72 procedures from January 2019 to December 2023, categorizing patients by pneumothorax and the severity of hemorrhage (grade 2 or higher). Radiodensity measurements were performed using lung window (LW) and MinIP (10-mm slab) images.

View Article and Find Full Text PDF

Introduction Debriefing in healthcare simulation is helpful in reinforcing learning objectives, closing performance gaps, and improving future practice and patient care. The Debriefing Assessment for Simulation in Healthcare (DASH) is a validated tool. However, localized rater training for the DASH has not been described.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!