Both visual and fluorescent sensors for Zn(2+) based on bis(pyrrol-2-yl-methyleneamine) platform.

Spectrochim Acta A Mol Biomol Spectrosc

Department of Chemistry and Chemical Engineering, Henan Polytechnic University, Jiaozuo 454000, PR China. Electronic address:

Published: September 2016

Two bis(pyrrol-2-yl-methyleneamine) chemo-sensors, 1, 3- and 1, 4-bis[3,4-dimethyl-5-ethyloxy -carbonyl-pyrrol-2-yl-methyleneamine]benzene (H2L(1) and H2L(2), respectively) have been synthesized and characterized, which exhibit high selectivity as off-on fluorescence sensors toward Zn(2+) in CH3CN/H2O (9:1, v/v) solution. The detection limits of both sensors are at the parts per million level. Moreover, the probes H2L(1) and H2L(2) could sense Zn(2+) by "naked eye" with a color change from colorless to yellow, and from yellow to dark yellow, respectively. To test the practical use of the probes, the determination of Zn(2+) in real water samples was also evaluated.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2016.05.014DOI Listing

Publication Analysis

Top Keywords

sensors zn2+
8
h2l1 h2l2
8
visual fluorescent
4
fluorescent sensors
4
zn2+
4
zn2+ based
4
based bispyrrol-2-yl-methyleneamine
4
bispyrrol-2-yl-methyleneamine platform
4
platform bispyrrol-2-yl-methyleneamine
4
bispyrrol-2-yl-methyleneamine chemo-sensors
4

Similar Publications

CQHC, a novel colorimetric fluorescent sensor, developed for the selective sensing of ions and well characterised, including SC-XRD. It demonstrated selective sensing for Co, Zn, Hg and F using absorbance titration at 420 nm, 446 nm and the binding constants estimated follows the order F > Co > Hg > Zn. On light of this, molecular logic gate was built for CQHC's selective multi-ion detection.

View Article and Find Full Text PDF

Cadmium is one of the most dangerous pollutants found in the environment, where it exists mainly due to human activities. High cadmium concentrations can cause serious problems, which is why the detection and determination of Cd is one of the most important tasks. Electroanalytical methods provide rapid and accurate results in the detection of cadmium in various solutions.

View Article and Find Full Text PDF

Heavy metals are life-threatening pollutions because of their great toxicity, long-term persistence in nature and their bioaccumulation in living organisms. In this work, we performed multivariate curve resolution-alternating least squares analysis of UV-Vis raw spectra received by a colorimetric sensor constructed on mercaptoundecanoic acid functionalized silver nanoparticles (AgNPs@11MUA) to detect Cd, Cu, Mn, Ni, and Zn in water. This combined approach allowed the rapid identification and quantification of multiple heavy metals and showed adequate sensitivity and selectivity, thus representing a promising analytical and computational method for both laboratory and field applications such as environmental safety and public health monitoring.

View Article and Find Full Text PDF

Bisquinoline-based fluorescent cadmium sensors.

Dalton Trans

January 2025

Laboratory for Molecular & Functional Design, Department of Engineering, Nara Women's University, Nara 630-8506, Japan.

Rational molecular design afforded fluorescent Cd sensors based on bisquinoline derivatives. Introduction of three methoxy groups at the 5,6,7-positions of the quinoline rings of BQDMEN (,'-bis(2-quinolylmethyl)-,'-dimethylethylenediamine) resulted in the reversal of metal ion selectivity in fluorescence enhancement from zinc to cadmium. Introduction of bulky alkyl groups and an ,-bis(2-quinolylmethyl)amine structure, as well as replacement of one of the two tertiary amine binding sites with an oxygen atom and the use of a 1,2-phenylene backbone significantly improved the Cd specificity.

View Article and Find Full Text PDF

Cellulose nanofibril enhanced ionic conductive hydrogels with high stretchability, high toughness and self-adhesive ability for flexible strain sensors.

Int J Biol Macromol

December 2024

State Key Laboratory of Metastable Materials Science and Technology, Hebei Key Laboratory of Applied Chemistry, Hebei Key Laboratory of Nanobiotechnology, Hebei Key Laboratory of Heavy Metal Deep-Remediation in Water and Resource Reuse, Yanshan University, Qinhuangdao 066004, China. Electronic address:

Preparation of ion-conductive hydrogels with excellent mechanics, good conductivity and adhesiveness is promising for flexible sensors, but remains a challenge. Here, we prepare a self-adhesive and ion-conductive hydrogel by introducing cellulose nanofibers (CNF) and ZnSO into a covalently-crosslinked poly (acrylamide-co-2-acrylamide-2-methyl propane sulfonic acid) (P(AM-co-AMPS)) network. Owing to the hydrogen bonding and metal coordination interactions among P(AM-co-AMPS) chains, CNF, and Zn, the resulting P(AM-co-AMPS)/CNF/ZnSO hydrogel exhibits high stretchability (1092 %), high toughness (244 kJ m), and skin-like elasticity (3.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!