Helical Centerline Stent Improves Patency: Two-Year Results From the Randomized Mimics Trial.

Circ Cardiovasc Interv

From the Department of Angiology, Universitäts-Herzzentrum Freiburg Bad Krozingen, Bad Krozingen, Germany (T.Z.); Sheffield Vascular Institute, Northern General Hospital, Sheffield, United Kingdom (P.A.G.); Center for Critical Limb Care, Riverside Methodist Hospital, Columbus, OH (G.M.A.); and Department of Bioengineering, Imperial College, London, United Kingdom (C.G.C.).

Published: June 2016

Background: Reintervention in the femoropopliteal artery is frequent and a major driver of cost-effectiveness. High wall shear generated by swirling blood flow is associated with reduced occurrence of atherosclerosis and restenosis. This trial investigated the clinical and hemodynamic outcomes of the BioMimics 3D self-expanding tubular nitinol stent with helical centerline geometry compared with a straight stent in the femoropopliteal artery.

Methods And Results: In a prospective, multicenter, randomized controlled trial, 76 patients with symptomatic peripheral arterial disease were randomized 2:1 to receive a helical or a straight stent. An independent core laboratory adjudicated angiographic and ultrasound parameters. The primary safety end point was freedom from a composite of all death, target limb amputation, and target lesion revascularization at 30 days. The primary effectiveness end point was freedom from clinically driven target lesion revascularization at 6 months. Patency was a secondary end point. Subjects were followed up for 2 years from intervention. The primary safety (1-sided P<0.01) and efficacy (1-sided P<0.001) end points for the helical stent were met. The proportion of patients treated with the helical stent who maintained patency at 12 and 24 months was 80% and 72%, respectively, compared with 71% and 55% for the control group. The difference was significant through 24 months (P=0.05). Freedom from clinically driven target lesion revascularization for the helical compared with straight stent was 91% versus 92% at 12 months and 91% versus 76% at 24 months.

Conclusions: Both groups had similar safety outcomes and clinically driven target lesion revascularization to 2 years. However, after placement of a BioMimics 3D helical stent, there was improved patency to 2 years.

Clinical Trial Registration: URL: http://www.clinicaltrials.gov. Unique identifier: NCT02163863.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCINTERVENTIONS.115.002930DOI Listing

Publication Analysis

Top Keywords

helical centerline
8
straight stent
8
primary safety
8
point freedom
8
target lesion
8
lesion revascularization
8
stent
4
centerline stent
4
stent improves
4
improves patency
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!