T2K reports its first measurements of the parameters governing the disappearance of ν[over ¯]_{μ} in an off-axis beam due to flavor change induced by neutrino oscillations. The quasimonochromatic ν[over ¯]_{μ} beam, produced with a peak energy of 0.6 GeV at J-PARC, is observed at the far detector Super-Kamiokande, 295 km away, where the ν[over ¯]_{μ} survival probability is expected to be minimal. Using a data set corresponding to 4.01×10^{20} protons on target, 34 fully contained μ-like events were observed. The best-fit oscillation parameters are sin^{2}(θ[over ¯]_{23})=0.45 and |Δm[over ¯]_{32}^{2}|=2.51×10^{-3}  eV^{2} with 68% confidence intervals of 0.38-0.64 and 2.26-2.80×10^{-3}  eV^{2}, respectively. These results are in agreement with existing antineutrino parameter measurements and also with the ν_{μ} disappearance parameters measured by T2K.

Download full-text PDF

Source
http://dx.doi.org/10.1103/PhysRevLett.116.181801DOI Listing

Publication Analysis

Top Keywords

ν[over ¯]_{μ}
12
off-axis beam
8
measurement muon
4
muon antineutrino
4
antineutrino oscillations
4
oscillations accelerator-produced
4
accelerator-produced off-axis
4
beam t2k
4
t2k reports
4
reports measurements
4

Similar Publications

Objective: To compare prostate cancer detection rates (CDRs) and pathology results with targeted prostate biopsy (TB) and systematic prostate biopsy (SB) in biopsy-naive men.

Methods: An in-patient control study of 82 men undergoing SB and subsequent TB in case of positive prostate MRI between 2015 and 2017 in the Jeroen Bosch Hospital, the Netherlands.

Results: Prostate cancer (PCa) was detected in 54.

View Article and Find Full Text PDF

Background: To overcome the limitations regarding two dimensional (2D) greyscale (GS) transrectal ultrasound (TRUS)-guided biopsy in prostate cancer (PCa) detection and tissue packaging in biopsy processing, there is an ongoing focus on new imaging and pathology techniques. A three-dimensional (3D) model of the prostate with biopsy needle guidance can be generate by the Navigo™ workstation (UC-care, Israel). The SmartBX™ system (UC-care, Israel) provides a prostate biopsy core preembedding method.

View Article and Find Full Text PDF

Purpose: To determine the value of a three-dimensional (3D) greyscale transrectal ultrasound (TRUS)-guided prostate biopsy system and biopsy core pre-embedding method on concordance between Gleason scores of needle biopsies and radical prostatectomy (RP) specimens.

Methods: Retrospective analysis of prostate biopsies and subsequent RP for PCa in the Jeroen Bosch Hospital, the Netherlands, from 2007 to 2016. Two cohorts were analysed: conventional 2D TRUS-guided biopsies and RP (2007-2013, n = 266) versus 3D TRUS-guided biopsies with pre-embedding (2013-2016, n = 129).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!