Some mass spectrometrists believe that searching for variable PTMs like phosphorylation of serine or threonine when using database-search algorithms to interpret peptide tandem mass spectra will increase false-positive matching. The basis for this is the premise that the algorithm compares a spectrum to both a nonphosphorylated peptide candidate and a phosphorylated candidate, which is double the number of candidates compared to a search with no possible phosphorylation. Hence, if the search space doubles, false-positive matching could increase accordingly as the algorithm considers more candidates to which false matches could be made. In this study, it is shown that the search for variable phosphoserine and phosphothreonine modifications does not always double the search space or unduly impinge upon the FDR. A breakdown of how one popular database-search algorithm deals with variable phosphorylation is presented.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/pmic.201500440 | DOI Listing |
Nat Commun
January 2025
J. Heyrovský Institute of Physical Chemistry, Czech Academy of Sciences, Prague, Czechia.
Single-molecule localization microscopy (SMLM) allows imaging beyond the diffraction limit. Detection of molecules is a crucial initial step in SMLM. False positive detections, which are not quantitatively controlled in current methods, are a source of artifacts that affect the entire SMLM analysis pipeline.
View Article and Find Full Text PDFAnal Chem
January 2025
School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100, China.
A novel dual-mode microfluidic sensing platform integrating photoelectrochemical (PEC) and fluorescence (FL) sensors was developed for the sensitive monitoring of heart fatty acid binding protein (h-FABP). First, BiVO/AgInS (BVAIS) composites with excellent photoelectric activity were synthesized as sensing matrices. The BVAIS heterojunction with a well-matched internal energy level structure provided a stable photocurrent.
View Article and Find Full Text PDFNMR Biomed
February 2025
Department of Radiology, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.
Susceptibility-weighted imaging (SWI) has been widely used in clinical contexts, in which the speed of acquisition is frequently a critical issue. In this study, we aim to test the feasibility of a deep learning (DL)-based reconstruction method for accelerating SWI acquisition in clinical settings. A total of 61 subjects were consecutively enrolled.
View Article and Find Full Text PDFClin Nucl Med
November 2024
From the Department of Nuclear Medicine.
Purpose: We aimed to compare the diagnostic performance of 68Ga-FAPI-04 (FAPI) in comparison to 68Ga-DOTATATE (SSTR) PET/CT for patients presenting with recurrent medullary thyroid carcinoma (MTC).
Patients And Methods: Sixteen MTC patients with elevated calcitonin levels (>150 pg/mL) underwent FAPI and SSTR PET/CT. Two nuclear medicine physicians evaluated all images, categorizing lesions into locoregional metastases, mediastinal lymph nodes (LNs), liver, and bone metastases.
Clin Nucl Med
February 2025
From the Department of Nuclear Medicine.
Purpose: We aimed to compare the diagnostic performance of 68Ga-FAPI-04 (FAPI) in comparison to 68Ga-DOTATATE (SSTR) PET/CT for patients presenting with recurrent medullary thyroid carcinoma (MTC).
Patients And Methods: Sixteen MTC patients with elevated calcitonin levels (>150 pg/mL) underwent FAPI and SSTR PET/CT. Two nuclear medicine physicians evaluated all images, categorizing lesions into locoregional metastases, mediastinal lymph nodes (LNs), liver, and bone metastases.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!