Function: require_once
This study evaluated the immunochromatographic (IC) assay "TECHLAB(®) E. HISTOLYTICA QUIK CHEK™" analysing 36 faecal samples and 7 cultured strains. This assay was compared to the methods performed in our laboratory for the diagnosis of amoebiasis. The IC assay revealed a detection limit of 103 trophozoites/g faeces and no cross-reactivity with other parasites and failed to detect E. histolytica antigen in frozen faeces. In our laboratory located in a non-endemic setting this assay could not replace the methods currently used for the diagnosis of amoebiasis.