With the increasing success of hip joint replacements, the average age of patients has decreased, patients have become more active and their expectations of the implant durability have risen. Thus, pre-clinical endurance tests on hip implants require defining realistic in vivo loads from younger and more active patients. These loads require simplifications to be applicable for simulator tests and numerical analyses. Here, the contact forces in the joint were measured with instrumented hip implants in ten subjects during nine of the most physically demanding and frequent activities of daily living. Typical levels and directions of average and high joint loads were extracted from the intra- and inter-individually widely varying individual data. These data can also be used to analyse bone remodelling at the implant-bone interface, evaluate tissue straining in finite element studies or validate analytical loading predictions, among other uses. The current ISO standards for endurance tests of implant stems and necks are based on historic analytical data from the 1970s. Comparisons of these test forces with in vivo loads unveiled that their unidirectional orientations deviate from the time-dependent in vivo directions during walking and most other activities. The ISO force for testing the stem is substantially too low while the ISO force for the neck better matches typical in vivo magnitudes. Because the magnitudes and orientations of peak forces substantially vary among the activities, load scenarios that reflect a collection of time-dependent high forces should be applied rather than using unidirectional forces. Based on data from ten patients, proposals for the most demanding activities, the time courses of the contact forces and the required cycle numbers for testing are given here. Friction moments in the joint were measured in addition to the contact forces. The moment data were also standardized and can be applied to wear tests of the implant. It was shown that friction only very slightly influences the stresses in the implant neck and shaft.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4873223 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0155612 | PLOS |
J Clin Med
January 2025
Department of Biomedical and Neuromotor Sciences (DIBINEM), Alma Mater Studiorum University of Bologna, 40123 Bologna, Italy.
Pseudotumors are defined as exuberant non-neoplastic inflammatory masses. This condition can be associated with hip and knee arthroplasty but has not been reported in Total Ankle Arthroplasty (TAA). This paper reports a pseudotumor that formed following TAA, highlighting its clinical presentation, management, and histopathology.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Orthopedics and Traumatology, Private Medicabil Hospital, 16140 Nilüfer/Bursa, Türkiye.
: Developmental dysplasia of the hip (DDH), defined by the malalignment of the femoral head and acetabulum, is a major precursor to coxarthrosis, posing substantial challenges during total hip arthroplasty (THA). Patients with coxarthrosis secondary to DDH often exhibit acetabular bone insufficiency, which makes challenging surgical reconstruction difficult. This study aimed to compare the radiologic and functional outcomes of robotically assisted and conventional manual THA techniques in patients with coxarthrosis secondary to Crowe type III-IV DDH.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Orthopaedic Surgery, Chosun University Hospital, 365 Pilmundae-ro, Dong-gu, Gwangju 61453, Republic of Korea.
Managing periprosthetic femoral fractures is challenging, particularly in osteoporotic patients with fragile bones. Revision with a long stem is commonly considered but may fail to provide adequate fixation and stability in fragile bones. A novel approach using sandwiched strut allografts and controlled bone crushing with robust cable fixation can offer mechanical support and provide secondary stability to the loosened femoral stem and can be considered a treatment option for low-demand patients.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Anesthesiology and Intensive Care, Astana Medical University, Astana 010000, Kazakhstan.
This case report highlights the use of continuous infusion of meropenem in a 42-year-old septic female patient with periprosthetic infection and end-stage renal disease receiving prolonged intermittent renal replacement therapy (PIRRT). Antibiotic infusion in patients receiving renal replacement therapy has its own peculiarities. There are many studies on the optimal dosing regimen for meropenem in renal dysfunction, but studies on the optimal infusion duration in these patients are limited.
View Article and Find Full Text PDFEur J Trauma Emerg Surg
January 2025
Ankara Etlik City Hospital, Ankara, Turkey.
Background: Cementless hip hemiarthroplasty is one of the options for the treatment of osteoporotic femoral neck fractures. Intraoperative periprosthetic femoral calcar fractures sometimes occur during the surgery, and the use of cerclage wiring to maintain the position and stability of the femoral stem and prevent the progression of the fracture. This study examines the outcomes of cerclage wiring to treat intraoperative periprosthetic calcar fractures in cementless hip hemiarthroplasty in osteoporotic femoral neck fractures.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!