Transcatheter aortic valve implantation (TAVI) is a fast-growing, exciting field of invasive therapy. During the last years many innovations significantly improved this technique. However, the prostheses are still associated with drawbacks. The aim of this study was to create cell-seeded biohybrid aortic valves (BAVs) as an ideal implant by combination of assets of biological and artificial materials. Furthermore, the influence of TAVI procedure on tissue-engineered BAV was investigated. BAV (n=6) were designed with decellularized homograft cusps and polyurethane walls. They were seeded with fibroblasts and endothelial cells isolated from saphenous veins. Consecutively, BAV were conditioned under low pulsatile flow (500 mL/min) for 5 days in a specialized bioreactor. After conditioning, TAVI-simulation was performed. The procedure was concluded with re-perfusion of the BAV for 2 days at an increased pulsatile flow (1100 mL/min). Functionality was assessed by video-documentation. Samples were taken after each processing step and evaluated by scanning electron microscopy (SEM), immunohistochemical staining (IHC), and Live/Dead-assays. The designed BAV were fully functioning and displayed physiologic behavior. After cell seeding, static cultivation and first conditioning, confluent cell layers were observed in SEM. Additionally, IHC indicated the presence of endothelial cells and fibroblasts. A significant construction of extracellular matrix was detected after the conditioning phase. However, a large number of lethal cells were observed after crimping by Live/Dead staining. Analysis revealed that the cells while still being present directly after crimping were removed in subsequent perfusion. Extensive regions of damaged cell-layers were detected by SEM-analysis substantiating these findings. Furthermore, increased ICAM expression was detected after re-perfusion as manifestation of inflammatory reaction. The approach to generate biohybrid valves is promising. However, damages inflicted during the crimping process seem not to be immediately detectable. Due to severe impacts on seeded cells, the strategy of living TE valves for TAVI should be reconsidered.

Download full-text PDF

Source
http://dx.doi.org/10.1111/aor.12683DOI Listing

Publication Analysis

Top Keywords

transcatheter aortic
8
aortic valve
8
valve implantation
8
endothelial cells
8
pulsatile flow
8
bav
5
cells
5
implantation living
4
living tissue-engineered
4
valves
4

Similar Publications

Paravalvular leak (PVL) was initially recognized as one of the most common complications after transcatheter aortic valve implantation (TAVI) and has been linked to adverse clinical outcomes, including mortality. This study aims to assess the long-term clinical effects of PVL in patients undergoing TAVI with the latest generation of transcatheter aortic valves, as part of the national observational prospective multicenter study OBSERVANT II. OBSERVANT II included all consecutive patients with severe aortic stenosis who underwent TAVI across 28 Italian centers from December 2016 to September 2018.

View Article and Find Full Text PDF

Myocardial work (MW) is a new echocardiographic parameter used in the assessment of cardiac energy expenditure. The aim of the current study was to evaluate changes in left ventricular MW parameters in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI). One hundred and thirty five consecutive patients who underwent TAVI at one center were evaluated before and after the procedure using transthoracic echocardiography (TTE) to assess the following MW indices: global constructive work (GCW), global wasted work (GWW), global work index (GWI) and global work efficiency (GWE).

View Article and Find Full Text PDF

Analysis of Calcium Patterns in the Thoracic Aorta and Clinical Outcomes of TAVR Patients Presenting with Porcelain Aorta.

J Clin Med

January 2025

Department of Cardiovascular Surgery, Institute Insure, German Heart Center Munich, School of Medicine & Health, Technical University of Munich, Lazarettstrasse 36, 80636 Munich, Germany.

: In the presence of porcelain aorta (PA), transcatheter aortic valve replacement (TAVR) has become a class I therapeutic indication for the treatment of severe aortic valve stenosis. To date, few studies have analyzed the clinical outcomes of TAVR in PA patients. We aim to analyze the calcification patterns of the thoracic aorta in PA patients and to evaluate their clinical implications for TAVR procedures.

View Article and Find Full Text PDF

The detection of unexpected findings (UF) during CT scans of patients undergoing TAVR is frequent; however, it is unclear whether such findings have a clinical impact on the TAVR pathway. We conducted a retrospective, single-center observational study enrolling patients who were candidates for TAVR. All enrolled patients underwent a CT scan before valve implantation.

View Article and Find Full Text PDF

A significant proportion of elderly patients referred to transcatheter aortic valve replacement (TAVR) do not experience an improvement of their symptoms. New tools are needed to better select candidates and avoid futile procedures. The objective of this study was to evaluate the impact of a new echocardiographic classification which assesses the consequences of chronic elevation of afterload on mortality and hospitalizations for heart failure (HF) in patients with severe AS undergoing TAVR.

View Article and Find Full Text PDF