A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Weak D type 67 in four related Canadian blood donors. | LitMetric

Weak D type 67 in four related Canadian blood donors.

Immunohematology

Canadian Blood Services, Medical Services and Innovation, Ottawa, Ontario, Canada.

Published: August 2016

Correct donor D typing is critical to prevent recipient alloimmunization. No method can detect all variants, and the immunogenicity of many variants is unknown. Routine ABO and D serologic typings are performed in our laboratory by automated microplate testing. Until 2011, routine confirmation of D- status of first-time donors was performed by the manual tube indirect antiglobulin test (IAT); this was replaced by automated solid-phase testing including weak D testing by IAT. Selected donors are investigated by other methods. We describe four weak D type 67 (RHD*01W.67) donors whose samples tested as D- by automated microplate and manual methods but were later determined to be D+ by automated solid-phase and RHD gene analysis. Solid-phase serologic and molecular typing results of all four donors were identical. It was identified that the donors are of English-Irish descent; two are brothers and the others are cousins. Transfusion of blood from one of these donors likely resulted in alloimmunization to D in one of three recipients tested since no other documented exposures were identified. Lookback studies determined that two other D- recipients were not alloimmunized.

Download full-text PDF

Source

Publication Analysis

Top Keywords

weak type
8
blood donors
8
automated microplate
8
automated solid-phase
8
donors
7
type canadian
4
canadian blood
4
donors correct
4
correct donor
4
donor typing
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!