Computed tomography is a widely used medical imaging technique that has high spatial and temporal resolution. Its weakness is its low sensitivity towards contrast media. Iterative reconstruction techniques (ITER) have recently become available, which provide reduced image noise compared with traditional filtered back-projection methods (FBP), which may allow the sensitivity of CT to be improved, however this effect has not been studied in detail. We scanned phantoms containing either an iodine contrast agent or gold nanoparticles. We used a range of tube voltages and currents. We performed reconstruction with FBP, ITER and a novel, iterative, modal-based reconstruction (IMR) algorithm. We found that noise decreased in an algorithm dependent manner (FBP > ITER > IMR) for every scan and that no differences were observed in attenuation rates of the agents. The contrast to noise ratio (CNR) of iodine was highest at 80 kV, whilst the CNR for gold was highest at 140 kV. The CNR of IMR images was almost tenfold higher than that of FBP images. Similar trends were found in dual energy images formed using these algorithms. In conclusion, IMR-based reconstruction techniques will allow contrast agents to be detected with greater sensitivity, and may allow lower contrast agent doses to be used.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4868985 | PMC |
http://dx.doi.org/10.1038/srep26177 | DOI Listing |
Clin Implant Dent Relat Res
February 2025
Department of Implantology, The Affiliated Hospital of Stomatology, School of Stomatology, Zhejiang University School of Medicine, Hangzhou, China.
Objectives: This study aimed to assess the effects of deproteinized bovine bone mineral with collagen (DBBMC) combined with deproteinized bovine bone mineral (DBBM) on facial alveolar bone augmentation in the anterior maxillary region.
Materials And Methods: Patients receiving dental implant placement with simultaneous lateral bone augmentation using DBBM (control group) or DBBMC combined with DBBM (test group) were included in the study. The radiographic assessment of facial alveolar bone, such as facial horizontal bone thickness (FHBT), facial vertical bone level (FVBL), and square of facial bone (SFB), was taken by cone beam computed tomography (CBCT).
Cancer Imaging
January 2025
Department of Surgery, Amsterdam UMC Location Vrije Universiteit Amsterdam, De Boelelaan 1117, Amsterdam, the Netherlands.
Background: Current diagnostic imaging modalities have limited ability to differentiate between malignant and benign pancreaticobiliary disease, and lack accuracy in detecting lymph node metastases. F-Prostate-Specific Membrane Antigen (PSMA) PET/CT is an imaging modality used for staging of prostate cancer, but has incidentally also identified PSMA-avid pancreatic lesions, histologically characterized as pancreatic ductal adenocarcinoma (PDAC). This phase I/II study aimed to assess the feasibility of F-PSMA PET/CT to detect PDAC.
View Article and Find Full Text PDFEur J Med Res
January 2025
Division of Radiology, Saraburi Hospital, Saraburi, Thailand.
Introduction: Stroke-associated pneumonia (SAP) is a major cause of mortality during the acute phase of stroke. The ADS score is widely used to predict SAP risk but does not include 24-h non-contrast computed tomography-Alberta Stroke Program Early CT Score (NCCT-ASPECTS) or red cell distribution width (RDW). We aim to evaluate the added prognostic value of incorporating 24-h NCCT-ASPECTS and RDW into the ADS score and to develop a novel prediction model for SAP following thrombolysis.
View Article and Find Full Text PDFBMC Infect Dis
January 2025
Department of Respiratory and Critical Care Medicine, Beijing Youan Hospital, Capital Medical University, Beijing, 100069, China.
Background: Chronic pulmonary abscess usually results from bacterial or mycobacterium infection, but rarely from aspergillosis. Chronic pulmonary aspergillosis is usually found in a person with structural lung disease or immunocompromise. Here, we report a case of chronic lung abscess of aspergillosis without immunocompromise, structural lung diseases or even clinical symptoms.
View Article and Find Full Text PDFJ Neuroimaging
January 2025
Department of Radiology, Division of Neuroradiology, Johns Hopkins Medical Center, Baltimore, Maryland, USA.
Background And Purpose: Prolonged venous transit (PVT), derived from computed tomography perfusion (CTP) time-to-maximum (T) maps, reflects compromised venous outflow (VO) in acute ischemic stroke due to large vessel occlusion (AIS-LVO). Poor VO is associated with worse clinical outcomes, but pre-treatment markers predictive of PVT are not well described.
Methods: We conducted a retrospective analysis of 189 patients with anterior circulation AIS-LVO who underwent baseline CT evaluation, including non-contrast CT, CT angiography, and CTP.