Assessing Wire Navigation Performance in the Operating Room.

J Surg Educ

Department of Orthopedics and Rehabilitation, The University of Iowa, Iowa City, Iowa; Department of Biomedical Engineering, The University of Iowa, Iowa City, Iowa; Department of Mechanical and Industrial Engineering, The University of Iowa, Iowa City, Iowa.

Published: March 2017

Objective: There are no widely accepted, objective, and reliable tools for measuring surgical skill in the operating room (OR). Ubiquitous video and imaging technology provide opportunities to develop metrics that meet this need. Hip fracture surgery is a promising area in which to develop these measures because hip fractures are common, the surgery is used as a milestone for residents, and it demands technical skill. The study objective is to develop meaningful, objective measures of wire navigation performance in the OR.

Design: Resident surgeons wore a head-mounted video camera while performing surgical open reduction and internal fixation using a dynamic hip screw. Data collected from video included: duration of wire navigation, number of fluoroscopic images, and the degree of intervention by the surgeon׳s supervisor. To determine reliability of these measurements, 4 independent raters performed them for 2 cases. Raters independently measured the tip-apex distance (TAD), which reflects the accuracy of the surgical placement of the wire, on all the 7 cases.

Setting: University of Iowa Hospitals and Clinics in Iowa City, IA-a public tertiary academic center.

Participants: In total 7 surgeries were performed by 7 different orthopedic residents. All 10 raters were biomedical engineering graduate students.

Results: The standard deviations for anteroposterior, lateral, and combined TAD measurements of the 10 raters were 2.7, 1.9, and 3.7mm, respectively, and interrater reliability produced a Cronbach α of 0.97. The interrater reliability analysis for all 9 video-based measures produced a Cronbach α of 0.99.

Conclusions: Several video-based metrics were consistent across the 4 video reviewers and are likely to be useful for performance assessment. The TAD measurement was less reliable than previous reports have suggested, but remains a valuable metric of performance. Nonexperts can reliably measure these values and they offer an objective assessment of OR performance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5131706PMC
http://dx.doi.org/10.1016/j.jsurg.2016.03.018DOI Listing

Publication Analysis

Top Keywords

wire navigation
12
navigation performance
8
operating room
8
interrater reliability
8
produced cronbach
8
performance
5
objective
5
assessing wire
4
performance operating
4
room objective
4

Similar Publications

Background: Severe vessel tortuosity may prevent a microcatheter from reaching a distal vessel. However, the Double-Wire Technique (DWT) may facilitate the procedure. The present study evaluated the feasibility and safety of guiding a 0.

View Article and Find Full Text PDF

In percutaneous pelvic trauma surgery, accurate placement of Kirschner wires (K-wires) is crucial to ensure effective fracture fixation and avoid complications due to breaching the cortical bone along an unsuitable trajectory. Surgical navigation via mixed reality (MR) can help achieve precise wire placement in a low-profile form factor. Current approaches in this domain are as yet unsuitable for real-world deployment because they fall short of guaranteeing accurate visual feedback due to uncontrolled bending of the wire.

View Article and Find Full Text PDF

Distinct contributions of BDNF/MEK/ERK1/2 signaling pathway components to whisker-dependent tactile learning and memory.

Brain Res

December 2024

Laboratory of Molecular Biology, Department of Biofunctional Analysis, Gifu Pharmaceutical University, Daigakunishi 1-25-4, Gifu 501-1196, Japan. Electronic address:

Whisker-mediated tactile perception is essential for rodent navigation, food acquisition, and social interactions. However, the molecular mechanisms underlying tactile information processing, learning, and memory have not been studied to the same extent as for other modalities. Using immunohistochemical staining, we investigated changes in regional c-Fos expression as an index of neuronal activity and phosphorylated (p)ERK1/2 as an index of ERK1/2 activity in mice trained on a tactile-cued 8-arm radial maze task.

View Article and Find Full Text PDF

Introduction: Recent literature continues to demonstrate the successful role of large-bore aspiration catheters in thrombus ingestion during mechanical thrombectomy. However catheter-to-microwire step-off and distal navigation are ongoing challenges in thrombectomy. A new to market 0.

View Article and Find Full Text PDF

Background And Objective: The early detection and early treatment of high-risk pulmonary nodules directly affect the long-term survival rate of patients. However, conventional nodule localization methods, such as hook-wire, technetium-99m, and methylene blue are associated with issues such as a high-frequency of complications, low patient tolerance, serious side effects, and inability to identify pigmented lungs. For patients who require segmentectomy, there is often a lack of effective path planning, resulting in insufficient resection margins or excessive loss of lung function.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!