Purpose: Fracture of orthodontic mini-implants during insertion is a limiting factor for their clinical success. The purpose of this study was to determine the fracture potential of commonly used self-drilling orthodontic mini-implants when placed into simulated thick, dense mandibular bone.
Materials And Methods: Six mini-implant systems were assessed for the potential for fracture (Aarhus, Medicon; Dual-Top, Jeil Medical; OrthoEasy, Forestadent; tomas-pin, Dentaurum; Unitek, 3M; and VectorTAS, Ormco). First, mini-implants were inserted manually, without predrilling, into bone substitutes (Sawbones) with a 3-mm-thick, dense (1.64 g/cm(3)) cortical layer. A custom-made insertion device was used for placement of mini-implants. A sixaxis force/torque transducer was secured at the base of the bone blocks to measure the maximum torque experienced during insertion. Measured insertion torques were compared with previously reported fracture torques, yielding a torque ratio (insertion torque as a percentage of fracture torque), which was used as an indicator of the potential for mini-implant fracture. Mini-implants that experienced torque ratios ≥ 75% upon insertion underwent further testing, following the manufacturer's recommendations for predrilling in thick, dense bone conditions.
Results: Significant differences in torque ratios were found among all mini-implants, except between OrthoEasy and Dual-Top, and OrthoEasy and VectorTAS. Overall, Aarhus had the highest torque ratio (91% ± 3%), with Unitek showing the lowest ratio (37% ± 3%). Aarhus and tomas-pin mini-implants displayed torque ratios ≥ 75% and experienced fracture upon insertion. When the manufacturer's specific predrilling recommendations were followed, no changes in torque ratio were found for Aarhus and tomas-pin. However, while Aarhus continued to fracture upon insertion, all tomas-pin mini-implants were inserted fully without fracture following predrilling.
Conclusion: These findings support the safe use of Unitek, VectorTAS, Dual-Top, and OrthoEasy self-drilling mini-implants in areas of 3-mm-thick, 1.64 g/cm(3) dense cortical bone without predrilling. Following predrilling, fractures did not occur with tomas-pin. For implants that continued to fracture after predrilling, other strategies may be required, such as the use of larger-diameter mini-implants in thick, dense bone conditions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.11607/jomi.4427 | DOI Listing |
Nat Phys
September 2024
School of Physics, Georgia Institute of Technology, Atlanta, GA, USA.
Bacteria often attach to surfaces and grow densely-packed communities called biofilms. As biofilms grow, they expand across the surface, increasing their surface area and access to nutrients. Thus, the overall growth rate of a biofilm is directly dependent on its "range expansion" rate.
View Article and Find Full Text PDFACS Nano
January 2025
School of Energy and Chemical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea.
Freestanding networked nanoparticle (NP) films hold substantial potential due to their high surface areas and customizable porosities. However, NPs with high surface energies and heterogeneous sizes or shapes present considerable challenges as they tend to aggregate, compromising their structural integrities. In this study, we report the scalable fabrication of ultrathin, bicontinuous, and densely packed carbon NP films via Pickering emulsion-mediated interfacial assembly.
View Article and Find Full Text PDFActa Parasitol
January 2025
Department of Molecular Biology and Genetics, Faculty of Arts and Science, Ordu University, Ordu, Türkiye.
Purpose: The brown marmorated stink bug, Halyomorpha halys (Hemiptera: Pentatomidae), is an invasive and a highly polyphagous species with a strong dispersal capacity. Unfortunately, there is currently no effective control method that can prevent or reduce the economic loss caused by this pest. Among natural enemies, microsporidia cause infections in insects so that they can generally shorten life span, reduce fertility and inhibit growth.
View Article and Find Full Text PDFCureus
December 2024
General Surgery, Hayatabad Medical Complex Peshawar, Peshawar, PAK.
Objective: The study aimed to investigate the rate of conversion from laparoscopic cholecystectomy (LC) to open cholecystectomy (OC) in our population and determine the potential risk factors associated with it. Understanding these factors helps surgeons predict complex cases and plan surgeries, reducing patient risks and improving outcomes.
Methodology: A cross-sectional observational study was conducted from June 1, 2022, to May 31, 2023, at Hayatabad Medical Complex, Peshawar, on 349 patients undergoing elective LC.
Int J Food Sci
January 2025
Institute of Microengineering and Nanoelectronics, Universiti Kebangsaan Malaysia, Bangi, Malaysia.
Two plasticizers with distinct properties are carefully studied in this research for their suitability in creating biocomposite edible film products. The study uncovers films' physical, tensile, and biodegradability attributes, using snakehead gelatin and ĸ-carrageenan in different concentrations, with sorbitol or glycerol as plasticizers. The biomaterials of the edible film consist of snakehead gelatin () 2% (/); ĸ-carrageenan at concentrations of 1%, 1.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!