The last recommendations of the International Commission on Radiological Protection for eye lens dose suggest an important reduction on the radiation limits associated with early and late tissue reactions. The aim of this work is to quantify and optimize the eye lens dose associated to nurse staff during positron emission tomography (PET) procedures. PET is one of the most important diagnostic methods of oncological and neurological cancer disease involving an important number of workers exposed to the high energy isotope F-18. We characterize the relevant stages as preparation and administration of monodose syringes in terms of occupational dose. A direct reading silicon dosimeter was used to measure the lens dose to staff. The highest dose of radiation was observed during preparation of the fluorodesoxyglucose (FDG) syringes. By optimizing a suitable vials' distribution of FDG we find an important reduction in occupational doses. Extrapolation of our data to other clinical scenarios indicates that, depending on the work load and/or syringes activity, safety limits of the dose might be exceeded.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0952-4746/36/2/299DOI Listing

Publication Analysis

Top Keywords

eye lens
12
lens dose
12
positron emission
8
emission tomography
8
tomography pet
8
pet procedures
8
dose
6
evaluation optimization
4
optimization occupational
4
occupational eye
4

Similar Publications

The Effect of Cataract Surgery on Stereoacuity, Balance, and Falls in Patients With Senile Cataract.

Eye Contact Lens

January 2025

Department of Ophthalmology (O.O.), Niğde Ömer Halisdemir University, Niğde, Turkey; Department of Ophthalmology (O.D.), Mersin University, Mersin, Turkey; Department of Ophthalmology (P.E.), Tarsus State Hospital, Mersin, Turkey; and Department of Ophthalmology (E.S.G.), Mersin State Hospital, Mersin, Turkey.

Objectives: To investigate the effect of cataract surgery on visual acuity, stereoacuity, balance, and falls in patients with senile cataract.

Methods: Prospective, cross-sectional study. The patients were divided into group 1 if the first surgery was performed on the dominant eye and group 2 on the nondominant eye.

View Article and Find Full Text PDF

Intraocular lens power calculation in cataract patients with keratoconus: Bayesian network meta-analysis.

Int Ophthalmol

January 2025

Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, No.1, Dong Jiao Min Xiang, Dong Cheng District, Beijing, 100730, China.

Purpose: To compare the accuracy of intraocular lens (IOL) power calculation formulas in cataract patients with keratoconus (KC).

Methods: This study followed the Preferred Reporting Items for Systematic Reviews and Meta-analysis statementand and was registered on PROSPERO (CRD42024568997). Pubmed, Web of Science, Cochrane Library, and EMBASE were searched for retrospective and prospective clinical studies published until October 2024.

View Article and Find Full Text PDF

Purpose: To describe a three-phase surgical approach for managing progressive visual decline in a patient with myopia magna and a history of epikeratophakia.

Methods: A 55-year-old woman with previous epikeratophakia surgery in both eyes experienced progressive visual deterioration. The three-phase approach included: (1) removal of the epikeratophakia lenticule, (2) cataract extraction with intraocular lens implantation, and (3) transepithelial topography-guided photorefractive keratectomy (trans-PRK).

View Article and Find Full Text PDF

Purpose: To compare the refractive accuracy of the Barrett True axial length (BTAL) formula, newly integrated into ARGOS, with that of the Barrett Universal II (BUII) formula calculated using axial length (AL) from IOL Master 700.

Setting: Private clinics in Kanagawa, Japan.

Design: Retrospective observational study.

View Article and Find Full Text PDF

Objectives: The objective of the investigation is to examine the long term efficacy, safety, and predictability of ICL-V4c implantation for high and super-high myopic patients in order to provide reliable guidance for the selection of refractive surgical procedures.

Methods: We reviewed 125 eyes from 64 patients who implanted ICL-V4c at the Refractive Surgery Center of West China Hospital in Chengdu, China, between May 2015 and January 2017. These eyes were divided into two groups based on their preoperative spherical equivalent (SE) degree: high myopia (≥ -10D) and super-high myopia groups (< -10D).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!