Pulsed magnets can produce magnetic fields largely exceeding those achieved with resistive or even hybrid magnets. This kind of magnet is indispensable in studies of field-induced phenomena which occur only in high magnetic field. A new high homogeneous pulsed magnet capable of producing field up to 55T and specially designed for NMR experiments was built and tested. Experimentally observed homogeneity of magnetic field in central part of the magnet is 10ppm over a sample volume of 2-3mm(3) at 12T and 30ppm at 47T, which are the best values ever reported for a pulsed magnet. Reasons which affect the field profile and reduce homogeneity at high field are discussed.