Purpose: The purpose of this study was to compare the insertion sites of the posterior horn between discoid and non-discoid lateral meniscus using magnetic resonance imaging (MRI).

Methods: Two hundred and twenty-seven patients who had MRI scans before surgery and underwent arthroscopy were enroled in this study. A coronal view showing the narrowest width of the midbody of the lateral meniscus was chosen to measure the widths of the entire tibial plateau and the midbody of the lateral meniscus. Considering the ratio of the meniscal width to the tibial plateau width, the patients were divided into non-discoid, incomplete discoid, and complete discoid groups. On a coronal view accurately showing the insertion of the posterior horn of the lateral meniscus, a distance between the peak of the lateral tibial eminence and the centre of the insertion of the posterior horn, and a width of the lateral tibial plateau between the lateral edge of the tibial plateau and the peak of the lateral tibial eminence were measured.

Results: The insertion centre of the posterior horn was located more medially in the incomplete and complete discoid groups than in the non-discoid group (p = 0.003, 0.010, respectively). When individual differences in the knee size were corrected, the insertion centre of the posterior horn in the incomplete discoid and complete discoid groups was located more medially than in the non-discoid group (p = 0.009, 0.003, respectively).

Conclusion: The insertion centre of the posterior horn of the lateral meniscus is located more medially to the apex of the lateral tibial eminence in the discoid group than in the non-discoid group. This finding needs to be considered for an accurate position of the posterior horn of lateral meniscus during the lateral meniscal allograft transplantation.

Level Of Evidence: IV.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00167-016-4161-7DOI Listing

Publication Analysis

Top Keywords

posterior horn
32
lateral meniscus
28
horn lateral
16
tibial plateau
16
lateral tibial
16
lateral
13
insertion posterior
12
complete discoid
12
discoid groups
12
tibial eminence
12

Similar Publications

Double extraocular muscle avulsion following injury by goat's horn.

Strabismus

January 2025

Department of Pediatric Ophthalmology, Strabismus and Neuro-Ophthalmology, Shroff's Charity Eye Hospital, New Delhi, India.

: Trauma to extraocular muscle without globe perforation is rare. This case report describes the clinical features and principles of repair of the simultaneous injury to two extraocular muscles sustained from a goat's horn. : Case records of the 36-year-old man who suffered trauma to his left eye were reviewed.

View Article and Find Full Text PDF

This study examined the effects of treadmill running (TR) regimens on craniofacial pain- and anxiety-like behaviors, as well as their effects on neural changes in specific brain regions of male mice subjected to repeated social defeat stress (SDS) for 10 days. Behavioral and immunohistochemical experiments were conducted to evaluate the impact of TR regimens on SDS-related those behaviors, as well as epigenetic and neural activity markers in the anterior cingulate cortex (ACC), insular cortex (IC), rostral ventromedial medulla (RVM), and cervical spinal dorsal horn (C2). Behavioral responses were quantified using multiple tests, while immunohistochemistry measured histone H3 acetylation, histone deacetylases (HDAC1, HDAC2), and neural activity markers (FosB and phosphorylated cAMP response element-binding protein (pCREB).

View Article and Find Full Text PDF

Background: Current knowledge on the microvascular anatomy of adult human menisci is based on cadaveric studies. However, considerable interindividual variation in meniscal microvascularization has been reported in recent studies with small sample sizes.

Purpose: To assess the association between patient characteristics and the depth of microvascularization of the meniscus.

View Article and Find Full Text PDF

A free-floating disc shaped polycarbonate-urethane ultra-high molecular weight polyethylene fiber reinforced medial compartment implant is designed for symptomatic postmedial meniscectomy syndrome. Because it is not sutured into place, an intact 2mm meniscus rim with intact anterior and posterior meniscal horns are required. In a recent 24-month follow-up study, only 64% of the original implants were retained.

View Article and Find Full Text PDF

Medial Open-Wedge High Tibial Osteotomy with Partial Meniscectomy and Without Cyst Excision for Popliteal Cysts: A Case Series.

Biomedicines

January 2025

Department of Orthopaedic Surgery, Hallym Sacred Heart University Hospital, Hallym University, Anyang-si 13496, Republic of Korea.

Popliteal cysts (PCs) are occasionally accompanied by knee osteoarthritis (OA) and varus malalignment. However, whether concomitant arthroscopic excision of PCs with medial open-wedge high tibial osteotomy (MOWHTO) improves the osteoarthritic environment remains unclear. Therefore, this study assessed serial changes in C-size, medial meniscus extrusion (MME), and cartilage status for up to 2 years following an MOWHTO.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!