A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Threonine versus isothreonine in synthetic peptides analyzed by high-resolution liquid chromatography/tandem mass spectrometry. | LitMetric

AI Article Synopsis

  • The study addresses the challenge of distinguishing between threonine and isothreonine in proteogenomic research due to sample preparation alterations.
  • Researchers utilized tandem mass spectrometry to analyze how these related peptides differ in their fragmentation patterns.
  • The findings reveal that isothreonine can be identified by distinct retention times and specific fragmentation characteristics, aiding accurate protein variant identification.

Article Abstract

Rationale: One of the problems in proteogenomic research aimed at identification of variant peptides is the presence of peptides with amino acid isomers of different origin in the analyzed samples. Among the most challenging examples are peptides with threonine and isothreonine (homoserine) in their sequences. Indeed, the latter residue may appear in vitro as a methionine substitution during sample preparation for shotgun proteome analysis. Yet, this substitution of Met to isoThr is not encoded genetically and should be unambiguously distinguished from, e.g., point mutations in proteins that result in Met conversion to Thr.

Methods: In this work we compared tandem mass (MS/MS) spectra produced by an Orbitrap mass spectrometer of Thr- and isoThr-containing tryptic peptides and found a distinctive feature in their collisionally activated fragmentation patterns.

Results: Up to 84% of MS/MS spectra for peptides containing isoThr residues have been positively specified. We also studied the differences in retention times for peptides containing Thr isoforms that can be further used for their distinction.

Conclusions: Threonine can be distinguished from isothreonine by its retention time and HCD fragmentation pattern, specifically relative intensity of the bn - product ion, which can be further used in proteomic research. Copyright © 2016 John Wiley & Sons, Ltd.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcm.7566DOI Listing

Publication Analysis

Top Keywords

ms/ms spectra
8
peptides
7
threonine versus
4
versus isothreonine
4
isothreonine synthetic
4
synthetic peptides
4
peptides analyzed
4
analyzed high-resolution
4
high-resolution liquid
4
liquid chromatography/tandem
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!