A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Radial nerve palsy after the use of an adjuvant hinged external fixator in a complex fracture-dislocation of the elbow: a case report and review of the literature. | LitMetric

Background: The combination of an elbow dislocation, a radial head fracture, and a coronoid process fracture is known as "terrible triad" injury of the elbow. This injury is one of the most challenging injuries of the musculoskeletal system and almost always causes instability of the elbow. The use of an adjuvant hinged external fixator in such injuries is still debated.

Case Presentation: In this case report we present a case of radial nerve palsy after setting up an adjuvant hinged external fixator in a complex fracture-dislocation of the elbow. The patient was a 39-year-old white man. A revision of his radial nerve was undertaken at 7 weeks. A radial nerve injury at two levels facing the humeral apex pins was found intraoperatively; the pins were carefully removed and partial nerve grafts done. The functional outcome at 18 months was excellent.

Conclusion: This case report highlights that the use of an adjuvant hinged external fixator in complex fracture -dislocation of the elbow is technically demanding and not without risk.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4866299PMC
http://dx.doi.org/10.1186/s13256-016-0904-9DOI Listing

Publication Analysis

Top Keywords

radial nerve
16
adjuvant hinged
16
hinged external
16
external fixator
16
fixator complex
12
case report
12
nerve palsy
8
complex fracture-dislocation
8
fracture-dislocation elbow
8
elbow
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!