Background: In this study, we performed a meta-analysis to identify whether minimally invasive plate osteosynthesis (MIPO) was superior to conventional fixation techniques (CFT) for treating humeral shaft fractures.

Methods: A systematic literature search was conducted up to February 2016 in ScienceDirect, Springer, MEDLINE, and PubMed databases for relevant papers that compared the outcomes of MIPO with CFT, such as open reduction with plate osteosynthesis (ORPO) and intramedullary nail (IMN) for treating humeral shaft fractures. Meta-analysis was performed with Review Manager 5.0 software.

Results: According to the search strategy, eight studies that covered 391 patients were enrolled, including four randomized controlled trials (RCTs), two prospective cohort trials, and two retrospective cohort trials. Our meta-analysis did not detect any significant difference between MIPO and CFT (IMN and ORPO) in terms of operative time, fracture union rate, and fracture union time. However, MIPO has a less rate of complications and iatrogenic radial nerve palsy than that of ORPO and higher adjacent joint function scores than those of IMN (p < 0.05).

Conclusions: Based on the present evidence, this meta-analysis suggested that MIPO was a better choice for treating humeral shaft fractures than CFT. However, more high-quality randomized trials are still needed to further confirm this conclusion in the future.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4864922PMC
http://dx.doi.org/10.1186/s13018-016-0394-xDOI Listing

Publication Analysis

Top Keywords

plate osteosynthesis
12
humeral shaft
12
minimally invasive
8
invasive plate
8
conventional fixation
8
fixation techniques
8
shaft fractures
8
fractures meta-analysis
8
treating humeral
8
mipo cft
8

Similar Publications

Comparative finite element analysis: internal fixation plate versus intramedullary nail for neer type III-VI proximal humeral fractur.

J Orthop Surg Res

January 2025

Department of Orthopedics, Beijing Chaoyang Hospital, Capital Medical University, 8 Gongren Tiyuchang Nanlu, Chaoyang District, Beijing, 100020, China.

Background: Finite element analysis (FEA) could advance the understanding of fracture fixation and guide the choice of surgical treatment. This study aimed to compare two internal fixation methods in the treatment of displaced proximal humeral fracture (PHF) through FEA.

Methods: Three-dimensional FEA model based on the left shoulder joint of a 67-year-old female patient with PHFs and osteoporosis was adopted, in order to analyze the fixation effect and load stress distribution of internal fixation plates with open reduction and intramedullary nails without opening the fracture in the treatment of Neer III-VI PHF.

View Article and Find Full Text PDF

A non-metallic PEEK topology optimization reconstruction implant for large mandibular continuity defects, validated using the MANDYBILATOR apparatus.

Sci Rep

January 2025

Department of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of Groningen, Hanzeplein 1, P.O. Box 30.001, 9700 RB, Groningen, The Netherlands.

In cases of large mandibular continuity defects resulting from malignancy resection, the current standard of care involves using patient-specific/custom titanium reconstruction plates along with autogenous grafts (fibula, scapula, or iliac crest segments). However, when grafts are not feasible or desired, only the reconstruction plate is used to bridge the gap. Unfortunately, metal osteosynthesis and reconstruction plates, including titanium, exhibit adverse effects such as stress-shielding and limitations in accurate postoperative irradiation (especially with proton-beam therapy).

View Article and Find Full Text PDF

The purpose of this study is to investigate the outcomes of the use of a 2.7 mm semitubular hook plate for internal fixation of unstable metaphyseal ulnar fractures. Between January 2015 and July 2019, 30 consecutive patients with a recent unstable distal ulnar fracture were included in this prospective case series.

View Article and Find Full Text PDF

Objective: This study aimed to evaluate the functional outcomes of three surgical management strategies for pilon fractures, including primary external fixation with delayed plating, external fixation with minimal internal fixation, and single-stage open reduction and internal fixation (ORIF) with plating.

Methods: This prospective cohort study included 34 patients with complex intra-articular fractures of the distal tibia (AO-OTA type 43-C) treated between June 2018 and December 2019. Patients were managed surgically based on the local skin condition and swelling, employing either primary-stage external fixation with delayed plating (Group A), external fixation with minimal internal fixation (Group B), or single-stage ORIF with plating (Group C).

View Article and Find Full Text PDF

The state-of-the-art approach to open reduction and fixation (ORIF) of zygoma fracture fragments is based on manual skills. Achieving high accuracy can be challenging. Our feasibility study on deceased body donors with artificial zygomatic fractures investigated whether virtual repositioning of the fractures and the use of customised 3D-printed titanium osteosynthesis plates was similar in accuracy to the conventional manual procedure, and whether the method was applicable in a clinical setting.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!