A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Inorganic Phosphorus and Potassium Are Putative Indicators of Delayed Separation of Whole Blood. | LitMetric

Objectives: The delayed separation of whole blood can influence the concentrations of circulating blood components, including metabolites and cytokines. The aim of this study was to determine whether clinical-biochemistry analytes can be used to assess the delayed separation of whole blood.

Methods: We investigated the plasma and serum concentrations of five clinical-biochemistry analytes and free hemoglobin when the centrifugation of whole blood stored at 4°C or room temperature was delayed for 4 hours, 6 hours, 24 hours, or 48 hours, and compared the values with those of matched samples that had been centrifuged within 2 hours after whole-blood collection.

Results: The inorganic phosphorus (IP) levels in the plasma and serum samples were elevated ≥ 1.5-fold when whole-blood centrifugation was delayed at room temperature for 48 hours. Furthermore, the IP levels in the plasma samples showed excellent assessment accuracy [area under the receiver-operating-characteristic curve (AUC) > 0.9] after a 48-hour delay in whole-blood separation, and high sensitivity (100%) and specificity (95%) at an optimal cutoff point. The IP levels in the serum samples also exhibited good assessment accuracy (AUC > 0.8), and high sensitivity (81%) and specificity (100%). The potassium (K(+)) levels were elevated 1.4-fold in the serum samples following a 48-hour delay in whole-blood separation. The K(+) levels showed excellent assessment accuracy (AUC > 0.9) following a 48-hour delay in whole-blood separation, and high sensitivity (95%) and specificity (91%) at an optimal cutoff point.

Conclusion: Our study showed that the IP and K(+) levels in the plasma or serum samples could be considered as putative indicators to determine whether whole-blood separation had been delayed for extended periods.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4850501PMC
http://dx.doi.org/10.1016/j.phrp.2015.11.003DOI Listing

Publication Analysis

Top Keywords

serum samples
16
whole-blood separation
16
delayed separation
12
plasma serum
12
levels plasma
12
assessment accuracy
12
48-hour delay
12
delay whole-blood
12
high sensitivity
12
inorganic phosphorus
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!