The aim of the present Monte Carlo study is to evaluate the variation of energy deposition in healthy tissues in the human eye which is irradiated by brachytherapy sources in comparison with the resultant dose increase in the gold nanoparticle (GNP)-loaded choroidal melanoma. The effects of these nanoparticles on normal tissues are compared between 103Pd and 125I as two ophthalmic brachytherapy sources. Dose distribution in the tumor and healthy tissues has been taken into account for both brachytherapy sources. Also, in certain points of the eye, the ratio of the absorbed dose by the normal tissue in the presence of GNPs to the absorbed dose by the same point in the absence of GNPs has been calculated. In addition, differences of the absorbed dose in the tumor observed in the comparison of simple water phantom and actual simulated human eye in presence of GNPs are also a matter of interest that have been considered in the present work. The difference between the eye globe and the water phantom is more obvious for 125I than that of the 103Pd when the ophthalmic dosimetry is done in the presence of GNPs. Whenever these nanoparticles are utilized in enhancing the absorbed dose by the tumor, the use of 125I brachytherapy source will greatly amplify the amount of dose enhancement factor (DEF) in the tumor site without inflicting much dam-age to healthy organs, when compared to the 103Pd source. For instance, in the concentration of 30 mg GNPs, the difference amongst the calculated DEF for 125I between these phantoms is 5.3%, while it is 2.45% for 103Pd. Furthermore, in Monte Carlo studies of eye brachytherapy, more precise definition of the eye phantom instead of a water phantom will become increasingly important when we use 125I as opposed to 103Pd.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690933 | PMC |
http://dx.doi.org/10.1120/jacmp.v17i3.5945 | DOI Listing |
Phys Eng Sci Med
January 2025
Department of Physics and Radiation Safety, Nepean Hospital, Penrith, New South Wales, Australia.
The radiation exposure to bystanders from nuclear medicine patients is a common concern raised in nuclear medicine departments. The GATE (Geant4 Application for Tomographic Emission) Monte Carlo radiation transport application was used to estimate the dose to a bystander. Two voxelised phantoms were utilised in a GATE Monte Carlo simulation as the radiation source and target.
View Article and Find Full Text PDFHeliyon
January 2025
Department of Clinical Microbiology and Infectious Diseases, Hospital General Universitario Gregorio Marañón, Madrid, Spain.
Background: Oritavancin (ORT) is a new single-dose lipoglycopeptide showing activity against staphylococci and vancomycin-resistant enterococci. However, there is no data regarding its potential use as a catheter lock solution are scarce. We constructed an model to analyze the efficacy and stability of an ORT lock solution against the biofilm of staphylococci and enterococci over 7 days at 37 °C.
View Article and Find Full Text PDFF1000Res
January 2025
Departments of Psychiatry, Neurology, Radiology, and Neuroscience, Washington University in St. Louis School of Medicine, St. Louis, MO, 63110, USA.
Reddy and Reddy (2014) discuss the optimal timing for lithium levels in patients taking once-daily extended-release lithium formulations. They argue for blood sampling 24 h after the previous dose rather than the standard 12 h. I interpret the data quite differently.
View Article and Find Full Text PDFClin Pharmacol Ther
January 2025
Division of Applied Regulatory Science, Office of Clinical Pharmacology, Office of Translational Sciences, Center for Drug Evaluation and Research, Food & Drug Administration, Silver Spring, Maryland, USA.
In response to increased illicit use of synthetic opioids, various μ-receptor antagonist formulations, with varied pharmacological characteristics, have been and are being developed. To understand how pharmacologic characteristics such as absorption rate and clearance rate affect reversal in treating community opioid overdose, we used our previously published translational opioid model. We adapted this model with in vitro receptor binding data and clinical pharmacokinetic data of three intranasal nalmefene formulations along with an intranasal naloxone formulation to study the reversal of fentanyl and carfentanil-induced respiratory depression in chronic opioid users.
View Article and Find Full Text PDFSci Rep
January 2025
Faculty of Computer and Information, South Valley University, Qena, 83523, Egypt.
Ra, Th, and K levels in various foods frequently consumed by Egyptians were determined using a gamma-ray spectrometer based on the germanium detector (HPGe). Activity concentrations of Ra, Th, and K were in the range of < 0.10 to 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!