Magnetic resonance spectroscopic imaging (MRSI) is a non-invasive technique able to provide the spatial distribution of relevant biochemical compounds commonly used as biomarkers of disease. Information provided by MRSI can be used as a valuable insight for the diagnosis, treatment and follow-up of several diseases such as cancer or neurological disorders. Obtaining accurate metabolite concentrations from in vivo MRSI signals is a crucial requirement for the clinical utility of this technique. Despite the numerous publications on the topic, accurate quantification is still a challenging problem due to the low signal-to-noise ratio of the data, overlap of spectral lines and the presence of nuisance components. We propose a novel quantification method, which alleviates these limitations by exploiting a spatio-spectral regularization scheme. In contrast to previous methods, the regularization terms are not expressed directly on the parameters being sought, but on appropriate transformed domains. In order to quantify all signals simultaneously in the MRSI grid, while introducing prior information, a fast proximal optimization algorithm is proposed. Experiments on synthetic MRSI data demonstrate that the error in the estimated metabolite concentrations is reduced by a mean of 41% with the proposed scheme. Results on in vivo brain MRSI data show the benefit of the proposed approach, which is able to fit overlapping peaks correctly and to capture metabolites that are missed by single-voxel methods due to their lower concentrations. Copyright © 2016 John Wiley & Sons, Ltd.

Download full-text PDF

Source
http://dx.doi.org/10.1002/nbm.3532DOI Listing

Publication Analysis

Top Keywords

spatio-spectral regularization
8
magnetic resonance
8
resonance spectroscopic
8
spectroscopic imaging
8
metabolite concentrations
8
mrsi data
8
mrsi
6
regularization improve
4
improve magnetic
4
imaging quantification
4

Similar Publications

In this paper, we study the problem of efficiently and effectively embedding the high-dimensional spatio-spectral information of hyperspectral (HS) images, guided by feature diversity. Specifically, based on the theoretical formulation that feature diversity is correlated with the rank of the unfolded kernel matrix, we rectify 3D convolution by modifying its topology to enhance the rank upper-bound. This modification yields a rank-enhanced spatial-spectral symmetrical convolution set (ReS -ConvSet), which not only learns diverse and powerful feature representations but also saves network parameters.

View Article and Find Full Text PDF

Achieving high classification performance is challenging due to non-stationarity and low signal-to-noise ratio (low SNR) characteristics of EEG signals. Spatial filtering is commonly used to improve the SNR yet the individual differences in the underlying temporal or frequency information is often ignored. This paper investigates motor imagery signals via orthogonal wavelet decomposition, by which the raw signals are decomposed into multiple unrelated sub-band components.

View Article and Find Full Text PDF

Objective: Brain-computer interfaces (BCI) that enables people with severe motor disabilities to use their brain signals for direct control of objects have attracted increased interest in rehabilitation. To date, no study has investigated feasibility of the BCI framework incorporating both intracortical and scalp signals.

Methods: Concurrent local field potential (LFP) from the hand-knob area and scalp EEG were recorded in a paraplegic patient undergoing a spike-based close-loop neurorehabilitation training.

View Article and Find Full Text PDF

Ensemble Regularized Common Spatio-Spectral Pattern (ensemble RCSSP) model for motor imagery-based EEG signal classification.

Comput Biol Med

August 2021

Biomedical Engineering Department, School of Electrical Engineering, Iran University of Science and Technology (IUST), Narmak, 16846-13114, Tehran, Iran. Electronic address:

The Brain-Computer interface system provides a communication path among the brain and computer, and recently, it is the subject of increasing attention. One of the most common paradigms of BCI systems is motor imagery. Currently, to classify motor imagery EEG signals, Common Spatial Patterns (CSP) are extensively used.

View Article and Find Full Text PDF

Compressive spectral video sensing (CSVS) systems obtain spatial, spectral, and temporal information of a dynamic scene through the encoding of the incoming light rays by using a temporal-static coded aperture (CA). CSVS systems use CAs with binary entries spatially distributed at random. The random spatial encoding of the binary CAs entails a poor quality in the reconstructed images even though the CSVS sensing matrix is incoherent with the sparse representation basis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!