Most shunt obstructions happen at the inlet of the ventricular catheter. Three hundred six infusion studies from 2007 to 2011 were classified as having a typical pattern of either proximal occlusion or patency. We describe different patterns of shunt ventricular obstruction.Solid block: Cerebrospinal fluid (CSF) aspiration was impossible. Baseline pressure was without pulse waveform (respiratory waveform may be visible). A quick increase of pressure to a level compatible with the shunt's setting was recorded in response to infusion. Distal occlusion of the shunt via transcutaneous compression resulted in a rapid increase in pressure to levels above 50 mmHg. This pattern was attributed to a solid ventricular block.Slit ventricles: At baseline, a pattern similar to that of the solid block was observed. After compression, the pressure increases, the pulse waveform appears, and the intracranial pressure is often stabilized at 25-40 mmHg. It is probable that previously slit ventricles were opened during the test.Partial block: In a partial block of the ventricular catheter by an in-growing choroid plexus, the pulse waveform at baseline was observed and CSF aspiration was possible. During infusion, the pressure increased, but the pulse amplitude disappeared. During the increase in the pressure in the shunt prechamber, the connection with the ventricles is disturbed by repositioning of the plexus.Infusion study via the shunt prechamber is able to visualize ventricular obstruction of the hydrocephalus shunt.

Download full-text PDF

Source
http://dx.doi.org/10.1007/978-3-319-22533-3_69DOI Listing

Publication Analysis

Top Keywords

ventricular catheter
12
pulse waveform
12
increase pressure
12
csf aspiration
8
shunt prechamber
8
shunt
7
pressure
7
ventricular
6
shunt testing
4
testing vivo
4

Similar Publications

Background: The discussion of Fontan fenestration is difficult because many institutions have different strategies over time. In our institute, we performed a non-fenestrated Fontan procedure for single-ventricular physiology as our definitive strategy.

Methods: Between August 1999 and December 2007, 72 consecutive patients with single-ventricle physiology underwent extracardiac total cavopulmonary connection without fenestration as our definitive strategy.

View Article and Find Full Text PDF

Atrial fibrillation (AF) catheter ablation is safe and effective, though rare cases of takotsubo syndrome (TTS) have been observed without proven causation. This review synthesizes TTS following AF ablation case reports and series. Until October 2024, PubMed/Medline, SCOPUS, and Google Scholar were searched for AF ablation and TTS case reports and series.

View Article and Find Full Text PDF

Background: Ventricular tachycardia (VT) in patients with cardiac sarcoidosis (CS) can lead to sudden cardiac death. The role of ventricular tachycardia ablation (VTA) in CS has been investigated in a few small, single-center, and larger observational studies, but the evidence still needs to be provided. This study aimed to investigate the clinical outcomes of VTA in patients with CS admitted with a diagnosis of VT.

View Article and Find Full Text PDF

Introduction: In patients with symptomatic, refractory atrial fibrillation the ablate and pace (A&P) strategy (pacemaker implantation followed by atrio-ventricular junction ablation (AVJA)) is superior to medical therapy in improving quality of life and prognosis. Despite its well-proven benefits, this invasive therapeutic option is still underutilized in clinical practice. The choice of pacing modality (right ventricular pacing, biventricular pacing, BVP, or conduction system pacing, CSP) is crucial and can have significant clinical implications.

View Article and Find Full Text PDF

Comparison of Catheter Ablation in Patients with Paroxysmal Non-valvular Atrial Fibrillation and Heart Failure with Preserved Ejection Fraction.

Int J Med Sci

January 2025

Department of Cardiology, The Second Xiangya Hospital, Central South University, Changsha 410011, Hunan Province, People's Republic of China.

The efficacy of radiofrequency ablation (RFA) in patients with atrial fibrillation (AF) and heart failure with preserved ejection fraction (HFpEF) has been established, but the efficacy and safety of cryoballoon ablation (CBA) and pulsed field ablation (PFA) remain unclear. This retrospective cohort study included 223 patients with paroxysmal non-valvular AF and HFpEF who underwent their first AF ablation between January 2017 and December 2021 and were divided into RFA (n = 77), CBA (n = 127), and PFA (n = 19) groups. After a mean follow-up of 11.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!