A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Low-dose volume perfusion computed tomography (VPCT) for diagnosis of solitary pulmonary nodules. | LitMetric

Objective: To characterize solitary pulmonary nodules (SPN) in terms of perfusion parameters using low-dose volume perfusion computed tomography (VPCT) and two different calculation methods, compare their results, look for interobserver agreement of measurements and investigate the feasibility of low-dose VPCT.

Materials And Methods: This study was approved by the local Institutional Review Board and all patients provided written informed consent. Seventy-one patients (mean age 60.8 years ±9.6) with solitary pulmonary nodules were enrolled. Low-dose VPCT was performed for 38.63s covering the involved lung (70kV, 120mAs, 22 consecutive volume measurements, 50mL iodinated contrast, flow rate 4mL/s). Mean blood flow (BF), blood volume (BV) and k-trans were determined both with the maximum slope+Patlak vs. deconvolution method. Additionally, the difference of VPCT parameters between different type lesions and normal tissue was analyzed. Interobserver agreement for all perfusion parameters was calculated using intraclass correlation coefficients (ICC). The effective radiation dose of the VPCT and the total CT scan protocol were recorded. All CT findings were histologically confirmed by surgical intervention.

Results: The mean lesion size was 18.6mm. Interobserver agreement measure with ICC shows high agreement between the measurements (κ=0.85). The effective radiation dose of the VPCT was 9.3mSv. The mean perfusion values for BF, BV and k-trans of 120.6mL/100g tissue/', 11.6mL/100g tissue/', and 18.5mL/100g tissue/' for the deconvolution method, and 50.1mL/100g tissue/', 11.6mL/100g tissue/' and 24.3mL/100g tissue/' for the maximum slope+Patlak method, which were significantly higher than those of normal muscle (20.7mL/100g tissue/', 2.6mL/100g tissue/', and 7.6mL/100g tissue/' for the deconvolution method and 10.9mL/100g tissue/', 3.1mL/100g tissue/' and 8.1mL/100g tissue/' for the maximum slope method). The best overall correlation between calculation methods was achieved for measurements of BF.

Conclusion: The low-dose volume perfusion CT of the solitary pulmonary nodules can effectively reduce the radiation dose and non-invasively assess perfusion of SPN within the entire lesion volume.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2016.03.026DOI Listing

Publication Analysis

Top Keywords

solitary pulmonary
16
pulmonary nodules
16
low-dose volume
12
volume perfusion
12
interobserver agreement
12
deconvolution method
12
radiation dose
12
tissue/'
12
perfusion computed
8
computed tomography
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!