Background: Machine perfusion is a promising strategy for donor heart preservation, but delivery of perfusate through the aorta may be limited by aortic valve incompetence. We hypothesized that retrograde machine perfusion preservation through the coronary sinus avoided this issue and allowed for recovery of donor hearts after long-term storage.

Methods: Canine hearts were procured after arrest with 1 liter University of Wisconsin Machine Perfusion Solution (UWMPS) and preserved for 14 hours by static hypothermic storage (Static group, n = 5) or retrograde machine perfusion through the coronary sinus (RP group, n = 5). Myocardial oxygen consumption (MVo2) and lactate were monitored in perfused hearts. Hearts were implanted and reperfused for 6 hours. The pre-load recruitable stroke work was determined as a measure of myocardial function. Cardiac enzyme release was quantified. Cell death was evaluated by TUNEL (terminal deoxynucleotidyltransferase-mediated deoxy uridine triphosphate nick-end label).

Results: MVo2 decreased initially then stabilized. Lactate accumulation was low in RP hearts. All RP hearts separated from cardiopulmonary bypass. All Static hearts required a return to bypass (p < .05). Pre-load recruitable stroke work in RP hearts was increased (55 ± 7 mm Hg) compared with Static (20 ± 11 mm Hg, p < .05) and did not differ from baseline values. Creatine kinase release was greater in Static group hearts (102 ± 16 IU/liter/g) than in RP hearts (51 ± 8 IU/liter/g, p < .05). The fraction of TUNEL-positive cells was higher in the Static group, but this difference was not significant.

Conclusions: Retrograde machine perfusion can preserve donor hearts for long intervals. Cardiac function after implantation suggested excellent myocardial protection. Retrograde machine perfusion appears promising for extending the donor ischemic interval and improving results of heart transplantation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.healun.2016.03.007DOI Listing

Publication Analysis

Top Keywords

machine perfusion
28
retrograde machine
16
coronary sinus
12
hearts
12
donor hearts
12
static group
12
perfusion preservation
8
hearts hearts
8
pre-load recruitable
8
recruitable stroke
8

Similar Publications

Novel noninvasive prediction for pulse pressure variation: a machine learning-based model.

Br J Anaesth

January 2025

Department of Anaesthesia, Rabin Medical Centre, Beilinson Hospital, Petach Tikva, Israel; Faculty of Medical and Health Sciences, Tel Aviv University, Tel Aviv, Israel. Electronic address:

View Article and Find Full Text PDF

A Comparative Study Between Cold Static Storage and Normothermic Ex-Situ Donor Heart Preservation in a Rat Model of Heterotopic Heart Transplantation.

J Surg Res

January 2025

Department of Thoracic and Cardiovascular Surgery, Chonnam National University Hospital and Medical School, Gwangju, Republic of Korea; Extracorporeal Circulation Research Team, Chonnam National University Hospital, Gwangju, Republic of Korea. Electronic address:

Introduction: Cold static storage (CSS) and normothermic ex-situ preservation are the most widely used donor heart preservation techniques worldwide. The current study compares both CSS and normothermic ex-situ preservation methods in terms of graft performance, morphologic changes, and acute immune response in an experimental model.

Method And Materials: Twenty rats underwent heterotopic abdominal heart transplantation after 2 h of CSS (group 1; n = 10) or normothermic ex-situ perfusion (group 2; n = 10).

View Article and Find Full Text PDF

Background: Kidney transplantation (KT) is the most effective treatment for end-stage renal disease. End-ischemic hypothermic machine perfusion (EI-HMP) has emerged as a promising method for preserving grafts before transplantation. This study aimed to compare graft function recovery in KT recipients of deceased brain-death (DBD) grafts preserved with EI-HMP versus static cold storage (SCS).

View Article and Find Full Text PDF

: Hypothermic oxygenated machine perfusion has emerged as a strategy to alleviate ischemic-reperfusion injury in liver grafts. Nevertheless, there is limited data on the effectiveness of hypothermic liver perfusion in evaluating organ quality. This study aimed to introduce a readily accessible real-time predictive biomarker measured in machine perfusate for post-transplant liver graft function.

View Article and Find Full Text PDF

: The rising use of liver grafts from donation after circulatory death (DCD) has been enabled by advances in normothermic regional perfusion (NRP) and machine perfusion (MP) technologies. We aimed to identify predictive biomarkers in DCD grafts subjected to NRP, followed by randomization to either normothermic machine perfusion (NMP) or dual hypothermic oxygenated perfusion (D-HOPE). : Among 57 DCD donors, 32 liver grafts were transplanted, and recipients were monitored for one week post-transplant.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!