Objective: To evaluate a modified electrode montage with respect to its effect on tACS-dependent modulation of corticospinal excitability and discomfort caused by neurosensory side effects accompanying stimulation.

Methods: In a double-blind cross-over design, the classical electrode montage for primary motor cortex (M1) stimulation (two patch electrodes over M1 and contralateral supraorbital area) was compared with an M1 centre-ring montage. Corticospinal excitability was evaluated before, during, immediately after and 15 minutes after tACS (10 min., 20 Hz vs. 30 s low-frequency transcranial random noise stimulation).

Results: Corticospinal excitability increased significantly during and immediately after tACS with the centre-ring montage. This was not the case with the classical montage or tRNS stimulation. Level of discomfort was rated on average lower with the centre-ring montage.

Conclusions: In comparison to the classic montage, the M1 centre-ring montage enables a more focal stimulation of the target area and, at the same time, significantly reduces neurosensory side effects, essential for placebo-controlled study designs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.brs.2016.04.009DOI Listing

Publication Analysis

Top Keywords

electrode montage
12
corticospinal excitability
12
centre-ring montage
12
montage
8
neurosensory side
8
side effects
8
evaluation modified
4
modified high-definition
4
high-definition electrode
4
montage transcranial
4

Similar Publications

Background: Resistant auditory verbal hallucination (AVH) remains a disabling symptom in schizophrenia. Transcranial direct current stimulation (tDCS) and its more targeted variant, high-definition tDCS (HD-tDCS), have shown promising results in reducing AVH. We aimed to determine the effects of adjunctive HD-tDCS on various dimensions of AVH in patients with schizophrenia.

View Article and Find Full Text PDF

Meta analysis of resting frontal alpha asymmetry as a biomarker of depression.

Npj Ment Health Res

January 2025

Clinical Research Center for Mental Disorders, Shanghai Pudong New Area Mental Health Center, School of Medicine, Tongji University, Shanghai, 200124, China.

This meta-analysis investigated resting frontal alpha asymmetry (FAA) as a potential biomarker for major depressive disorder (MDD). Studies included articles utilizing FAA measure involving EEG electrodes (F3/F4, F7/F8, or Fp1/Fp2) and covering both MDD and controls. Hedges' d was calculated from FAA means and standard deviations (SDs).

View Article and Find Full Text PDF

Transcutaneous spinal direct current stimulation (TSDCS) has the potential to modulate spinal circuits and induce functional changes in humans. Nevertheless, differences across studies on basic parameters used and obtained metrics represent a confounding factor. Computer simulations are instrumental in improving the application of the TSDCS technique.

View Article and Find Full Text PDF

Diagnostic accuracy of reduced electroencephalography montages for seizure detection: A frequentist and Bayesian meta-analysis.

Neurophysiol Clin

January 2025

School of Public Health, College of Public Health, Taipei Medical University, Taipei, Taiwan; Department of Emergency Medicine, Taipei Medical University Hospital, Taipei, Taiwan; Department of Public Health, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan; Center of Evidence-Based Medicine, Taipei Medical University Hospital, Taipei, Taiwan; Department of Medical Research, Taipei Medical University Hospital, Taipei, Taiwan. Electronic address:

Aim: To evaluate the diagnostic accuracy of reduced montage electroencephalography (EEG) for seizure detection and provide evidence-based recommendations.

Methods: Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, we conducted a diagnostic meta-analysis to assess the sensitivity and specificity of reduced EEG montages in detecting seizure activity. A hierarchical summary receiver operating characteristic curve (HSROC) model was used to estimate the area under the curve (AUC).

View Article and Find Full Text PDF

Transcranial direct current stimulation in patients with depression: An electric field modeling meta-analysis.

J Affect Disord

January 2025

Mondor University Hospitals, INSERM U955, Institut Mondor de La Recherche Biomédicale (IMRB), University of Paris Est Créteil, Équipe Neuropsychiatrie Translationnelle, Créteil, France; NeuroSpin, Neuroimaging Platform, CEA, UNIACT Lab, PsyBrain Team, Saclay, France. Electronic address:

Transcranial Direct Current Stimulation (tDCS) has shown potential in modulating cortical activity and treating depression. Despite its promise, variability in electrode montage configurations and electric field strength across studies has resulted in inconsistent outcomes. Traditional meta-analytic methods assessing the effect of tDCS in depression typically do not compare tDCS montage and the anatomical distribution of electric field, which is a major source of inter-experimental variability.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!