Purpose: To measure the variations in length during flexion and internal tibial rotation of the 3 different femoral insertions of the anterolateral ligament (ALL) while maintaining a fixed tibia insertion.
Methods: Twelve fresh-frozen cadaver knees were analyzed using a navigation system. Maximal distance variations of the 3 different anatomic femoral insertions of the ALL were measured during knee flexion and internal tibial rotation at 20° (IR20°) and 90° (IR90°). The 3 different femoral attachments were, as published, at the center of the lateral epicondyle, distal and anterior from this position, and proximal and posterior. Each of these 3 femoral insertions was coupled to the same tibial insertion at the tibial margin, halfway between the tip of the fibular head and the prominence of the Gerdy tubercle.
Results: During IR20°, variation in the distance between paired points is not different between the proximal-posterior, epicondyle, and distal-anterior femoral insertions. These variations were statistically different during IR90° for the 3 different femoral locations. In increasing degrees of flexion, there was a length decrease between paired points observed with the proximal-posterior position. A length increase was observed for both the epicondyle location and the distal-anterior location.
Conclusions: The ALL did not reveal an isometric behavior at any of the femoral insertion locations but had different length change patterns during knee flexion and internal tibial rotation at 90°. The proximal and posterior to epicondyle femoral position is the only position with a favorable isometry, as shown by being tight in extension and in internal rotation at 20° and then relaxed when the knee goes to flexion at 120° and during internal rotation at 90°.
Clinical Relevance: Clinical relevance is significant with respect to optimizing the femoral position of an ALL reconstruction.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.arthro.2016.02.007 | DOI Listing |
J Robot Surg
January 2025
The Third Ward of Orthopaedic Department, General Hospital of Ningxia Medical University, 804 Shengli South Street, Hui Autonomous Region, Yinchuan, Ningxia, 750004, People's Republic of China.
The purpose of this study is to assess the safety and effectiveness of TiRobot-assisted treatment for femoral neck fractures, in comparison to traditional freehand treatment methods. Throughout the research process, we conducted an extensive literature search across numerous databases, including PubMed, EMBASE, Cochrane Library, Web of Science, China National Knowledge Infrastructure (CNKI), CQVIP, and Wanfang. Based on the literature screening criteria, we selected six studies, encompassing 358 cases of femoral neck fracture patients, for this meta-analysis.
View Article and Find Full Text PDFJ Orthop Sci
January 2025
Department of Orthopedics, First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning 116011, China. Electronic address:
Purpose: A finite element analysis was performed to simulate the biomechanical differences between anterior-posterior (AP) direction and posterior-anterior (PA) direction placement of two cannulated screws in Hoffa fractures.
Methods: Computed tomography images of an healthy male volunteer were used to simulate Letenneur Ⅰ, Ⅱa, Ⅱb, Ⅱc, Ⅲ Hoffa fractures, and two groups of screw internal fixation models were constructed. Two 6.
J Crit Care
January 2025
Division of Pulmonary and Critical Care Medicine, University of Maryland School of Medicine, Baltimore, MD, USA.
Purpose: This study evaluated the impact of choosing the right versus left internal jugular vein (IJV) for initial central venous catheter (CVC) placement on hemodialysis catheter-related outcomes in critically ill patients.
Materials And Methods: Medical records from the University of Maryland Medical Center were reviewed for adult critical care patients who received an IJV CVC between January 1, 2019, and December 31, 2022, and later required an additional temporary hemodialysis catheter.
Results: The study included 214 patients, with 100 (46.
Calcif Tissue Int
January 2025
Orthopaedic Research Laboratory, Department of Orthopedic Surgery and Traumatology, Odense University Hospital & Department of Clinical Research, University of Southern Denmark, V18-812B-1, Etage 1, Bygning 45.4, Nyt Sund, SDU Campus 5230, Odense, Denmark.
There is an increasing demand for a suitable bone substitute to replace current clinical gold standard autografts or allografts. Majority of previous studies have focused on the early effects of substitutes on bone formation, while information on their long-term efficacies remains limited. This study investigated the efficacies of natural hydroxyapatite (nHA) derived from oyster shells and synthetic hydroxyapatite mixed with collagen (COL/HA) or chitosan (CS/HA) on bone regeneration and implant fixation in sheep.
View Article and Find Full Text PDFCVIR Endovasc
January 2025
Radiology Department, The Princess Alexandra Hospital, Hamstel Road, Harlow, CM20 1QX, UK.
Background: This is a single-centre prospective observational study examining radial access in 62 Prostatic Artery Embolisation (PAE) procedures. Evaluation of left radial artery diameter using high frequency ultrasound before and after administration of sublingual glycerl trinitrate (GTN). Pre-procedure questionnaires calculating symptom severity score compared with post-procedure.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!