Ratiometric QD-FRET Sensing of Aqueous H2S in Vitro.

Anal Chem

Department of Chemistry, University of Illinois at Chicago, 845 West Taylor Street, Chicago, Illinois 60607-7061, United States.

Published: June 2016

We report a platform for the ratiometric fluorescent sensing of endogenously generated gaseous transmitter H2S in its aqueous form (bisulfide or hydrogen sulfide anion) based on the alteration of Förster resonance energy transfer from an emissive semiconductor quantum dot (QD) donor to a dithiol-linked organic dye acceptor. The disulfide bridge between the two chromophores is cleaved upon exposure to bisulfide, resulting in termination of FRET as the dye diffuses away from the QD. This results in enhanced QD emission and dye quenching. The resulting ratiometric response can be correlated quantitatively to the concentration of bisulfide and was found to have a detection limit as low as 1.36 ± 0.03 μM. The potential for use in biological applications was demonstrated by measuring the response of the QD-based FRET sensor microinjected into live HeLa cells upon extracellular exposure to bisulfide. The methodology used here is built upon a highly multifunctional platform that offers numerous advantages, such as low detection limit, enhanced photochemical stability, and sensing ability within a biological milieu.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4899257PMC
http://dx.doi.org/10.1021/acs.analchem.6b01310DOI Listing

Publication Analysis

Top Keywords

exposure bisulfide
8
detection limit
8
ratiometric qd-fret
4
qd-fret sensing
4
sensing aqueous
4
aqueous h2s
4
h2s vitro
4
vitro report
4
report platform
4
platform ratiometric
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!