Surgical procedures in the pelvic region are very challenging because of the complex anatomy of this region. "Corona mortis" is a term used to describe retro-pubic anastomosis between the obturator and external iliac vessels. It is considered as a key structure as significant haemorrhage may occur if the vessels are cut accidentally during pelvic surgeries. Earlier studies have documented a high frequency of venous anastomosis compared to its arterial counterpart. The objective of our study was to document the prevalence of venous corona mortis in South Indian human adult cadaveric pelvises. We conducted this study on 73 cadaveric pelvic halves. Out of the 73 hemi pelvises, 36 were normal without any variations of the obturator vessels while 37 hemi pelvises (51%) showed the presence of abnormal obturator vessels which proves to be a very high incidence in terms of variations. Out of the 37 hemi pelvises, 25 (68%) showed the presence of 2 obturator veins, out of which 1 was normal and the other was an abnormal obturator vein. 8 hemi pelvises (22%) had only abnormal obturator vein. Most of the abnormal obturator veins drained into the external iliac vein, while two veins drained into inferior epigastric veins. Venous corona mortis is said to be frequently encountered during surgery and is considered to be as important as arterial corona mortis in its clinical implications. Individual evaluation of this risky anatomical structure should be done prior to any surgical interventions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.injury.2016.04.032 | DOI Listing |
Eur J Orthop Surg Traumatol
July 2024
Department of Orthopaedic Surgery, University of Louisville, 550 S. Jackson St., 1st Floor ACB, Louisville, KY, 40202, USA.
Introduction: Computerized surgical navigation system guidance can improve bone tumor surgical resection accuracy. This study compared the 10-mm planned resection margin agreement between simulated pelvic-region bone tumors (SPBT) resected using either skin fiducial markers or Kirschner (K)-wires inserted directly into osseous landmarks with navigational system registration under direct observation. We hypothesized that skin fiducial markers would display similar resection margin accuracy.
View Article and Find Full Text PDFArthroscopy
October 2024
Section of Young Adult Hip Surgery, Division of Sports Medicine, Department of Orthopaedic Surgery, Rush Medical College of Rush University, Rush University Medical Center, Chicago, Illinois, U.S.A.. Electronic address:
Purpose: To investigate whether allograft substitutes may be used to restore suctional seal properties with labral augmentation, the purpose of the current study was to evaluate the biomechanical properties of the labral suction seal under several scenarios, including: (1) intact labrum, (2) rim preparation, (3) labral repair, (4) labral augmentation with iliotibial band (ITB), and (5) labral augmentation with a dermis allograft.
Methods: Eleven hemi-pelvises were dissected to the level of the labrum and placed in a material testing system for biomechanical axial distraction. Each specimen was compressed to 250 newtons (N) and distracted at 10 mm/s while load, crosshead displacement, and time were continuously recorded.
Arthroplast Today
February 2024
Department of Orthopaedic Surgery, Baylor Scott & White Hip Preservation Center, McKinney, TX, USA.
Background: Periacetabular osteotomy (PAO) is an effective surgical procedure for managing acetabular dysplasia. The purpose of this study was to analyze the biomechanical properties of novel PAO constructs that incorporate orthopaedic trauma techniques. We hypothesize that these fixation methods will create a stiffer construct that tolerates higher loads to failure.
View Article and Find Full Text PDFMedicina (Kaunas)
December 2023
Department of Radiology and Medical Imaging, University of Medicine and Pharmacy Carol Davila, 050474 Bucharest, Romania.
: The purpose of the current paper is to present our study on the variability in the prostatic artery origin, discuss the less frequent origins, and present the challenges of the prostatic artery embolization (PAE) procedure, thus aiding young interventional radiologists. : We studied the origins of the prostatic artery on digital subtraction angiography (DSA) examinations from PAE procedures on 35 male pelvises (70 hemi-pelvises). : Our study has demonstrated that the most frequent origin of the prostatic artery (PA) is the internal pudendal artery (IPA), 37.
View Article and Find Full Text PDFMedicina (Kaunas)
June 2023
Department of Trauma, University Hospital Zurich, 8091 Zurich, Switzerland.
: Minimally invasive surgeries for acetabulum fracture fixation are gaining popularity due to their known advantages versus open reduction and internal fixation. Antegrade or retrograde screw fixation along the long axis of the posterior column of the acetabulum is increasingly applied in surgical practice. While there is sufficient justification in the literature for the application of the anterior approach, there is a deficit of reports related to the posterior approach.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!