Over the last decade, the way to monitor hemodynamics at the bedside has evolved considerably in the intensive care unit as well as in the operating room. The most important evolution has been the declining use of the pulmonary artery catheter along with the growing use of echocardiography and of continuous, real-time, minimally or totally non-invasive hemodynamic monitoring techniques. This article, which is the result of an agreement between authors belonging to the Cardiovascular Dynamics Section of the European Society of Intensive Care Medicine, discusses the advantages and limits of using such techniques with an emphasis on their respective place in the hemodynamic management of critically ill patients with hemodynamic instability.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00134-016-4375-7 | DOI Listing |
Front Pharmacol
January 2025
Department of Emergency, Peking University People's Hospital, Beijing, China.
Ceftriaxone is widely used in clinical practice for its efficacy against infections. However, its increasing association with life-threatening immune hemolytic reactions urge clinicians to enhance recognition and maintain sharp vigilance. This report details a rare and severe case of ceftriaxone-induced hemolytic anemia (CIHA), hemodynamic instability and hemolytic crisis in a 54-year-old woman after intravenous infusion of ceftriaxone following a respiratory infection.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Neurology, University of Texas Southwestern Medical Center, Dallas, TX, 75390, USA.
Blood pressure (BP) is a dynamic measure that is frequently discussed in static terms. There exist many limitations in current documentation systems whereby documented BP values may not be reflective of the dynamic variability of BP. This study used an observational, prospective, non-randomized study design to examine the variability in BP response during intravenous vasoactive medication administration in an intensive care unit setting.
View Article and Find Full Text PDFUltrasound Obstet Gynecol
January 2025
Ultrasound Unit, Helen Schneider Hospital for Women, Rabin Medical Center, Beilinson Hospital, Petach Tikva, Israel.
Objective: Portosystemic shunts in growth-restricted fetuses are more common than previously thought. We aimed to describe fetuses with growth restriction and transient oligohydramnios in which a congenital intrahepatic portosystemic shunt (CIPSS) was noted during follow-up.
Methods: This was a retrospective study of all fetuses diagnosed with growth restriction and transient oligohydramnios during a 5-year period in a large tertiary referral center.
J Clin Monit Comput
January 2025
IRCCS Humanitas Research Hospital, via Manzoni 56, Rozzano - Milan, 20089, Italy.
Fluids are given with the purpose of increasing cardiac output (CO), but approximately only 50% of critically ill patients are fluid responders. Since the effect of a fluid bolus is time-sensitive, it diminuish within few hours, following the initial fluid resuscitation. Several functional hemodynamic tests (FHTs), consisting of maneuvers affecting heart-lung interactions, have been conceived to discriminate fluid responders from non-responders.
View Article and Find Full Text PDFCirc Heart Fail
January 2025
Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Germany. (R.P., J.S.H., D.B., A.S.M., M.H., A.Z., G.D., J.D.S., A.F.P., A.W., A.R., B.S.).
Background: Consensus regarding on-support evaluation and weaning concepts from Impella 5.5 support is scarce. The derived left ventricular end-diastolic pressure (dLVEDP), estimated by device algorithms, is a rarely reported tool for monitoring the weaning process.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!