In recent years, high pressure freezing and freeze substitution have been widely used for electron microscopy to reveal viral and cellular structures that are difficult to preserve. Vaccinia virus, a member of the Poxviridae family, presents one of the most complex viral structures. The classical view of vaccinia virus structure consists of an envelope surrounding a biconcave core, with a lateral body in each concavity of the core. This classical view was challenged by Peters and Muller (1963), who demonstrated the presence of a folded tubular structure inside the virus core and stated the difficulty in visualizing this structure, possibly because it is labile and cannot be preserved by conventional sample preparation. Therefore, this tubular structure, now called the nucleocapsid, has been mostly neglected over the years. Earlier studies were able to preserve the nucleocapsid, but with low efficiency. In this study, we report the protocol (and troubleshooting) that resulted in preservation of the highest numbers of nucleocapsids in several independent preparations. Using this protocol, we were able to demonstrate an interdependence between the formation of the virus core wall and the nucleocapsid, leading to the hypothesis that an interaction exists between the major protein constituents of these compartments, A3 (core wall) and L4 (nucleocapsid). Our results show that high pressure freezing and freeze substitution can be used in more in-depth studies concerning the nucleocapsid structure and function.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jsb.2016.05.001DOI Listing

Publication Analysis

Top Keywords

high pressure
12
pressure freezing
12
freezing freeze
12
freeze substitution
12
vaccinia virus
12
classical view
8
tubular structure
8
virus core
8
core wall
8
wall nucleocapsid
8

Similar Publications

The EFSA Panel on Food Contact Materials (FCM) assessed the safety of the recycling process NGR LSP (EU register number RECYC328). The input is hot washed and dried poly(ethylene terephthalate) (PET) flakes mainly originating from collected post-consumer PET containers, with no more than 5% PET from non-food consumer applications. The flakes are dried (step 2), melted in an extruder (step 3) and decontaminated during a melt-state polycondensation step under high temperature and vacuum (step 4).

View Article and Find Full Text PDF

This study investigates the safety of three different daily dosages of a liquid blend containing kava and kratom (Feel Free® Classic Tonic {FFCT}) in healthy adults over six consecutive days of supplementation. Both kava and kratom have been used traditionally for hundreds of years, but there is limited data on the combined safety of these ingredients. In this randomized, double-blind, placebo-controlled trial, the participants were assigned to receive one of three daily dosages of FFCT or placebo.

View Article and Find Full Text PDF

Background/purpose: High gold (Au) alloys have many advantages, such as good mechanical properties and stable chemical properties for dental restoration. The purpose of this investigation was to investigate the effect of zirconia (ZrO)-magnesia (MgO)-based investment combined with an argon arc vacuum pressure (Ar-arc VP) casting process on the recasting of high Au alloys.

Materials And Methods: The recasting Au alloys were compared between the control group of conventional SiO-based investment/horizontal centrifugal (HC) casting and the experimental group of ZrO-MgO-based investment/Ar-arc VP die casting.

View Article and Find Full Text PDF

The purpose of the study was to compare heart rate (HR), systolic blood pressure (SBP), and diastolic blood pressure (DBP) following high load resistance exercise (HLRE) and blood flow restriction exercise (BFRE) with a knee wrap (kBFRE) and pneumatic cuff (pBFRE). Eleven men (N = 9) and women (N = 2) participated. HR, SBP, and DBP were collected at Rest, immediately post exercise (IP), 10-, 30-, and 45-minutes post exercise.

View Article and Find Full Text PDF

Examining Changes in Pain Sensitivity Following 8 Minutes of Cycling at Varying Exercise Intensities.

Int J Exerc Sci

December 2024

Rehabilitation and Modulation of Pain (RAMP) Lab, Institute of Exercise Physiology and Rehabilitation Science, University of Central Florida, Orlando, FL, USA.

This study assessed the effect of an eight-minute cycling intervention using varying intensities on exercise-induced hypoalgesia (EIH). The main objective of this study was to examine the effect of varying intensities on pressure pain threshold (PPT) and heat pain threshold (HPT) at the thigh and forearm, tested pre- and post-cycling intervention. Healthy male participants ( = 16) performed a graded exercise test on a cycle ergometer to establish their peak power output (PPO).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!