A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Joint enhancement strategy applied in ECL biosensor based on closed bipolar electrodes for the detection of PSA. | LitMetric

Joint enhancement strategy applied in ECL biosensor based on closed bipolar electrodes for the detection of PSA.

Talanta

State Key Laboratory of Analytical Chemistry for Life Science and Collaborative Innovation Center of Chemistry for Life Sciences, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China.

Published: July 2016

A highly sensitive electrogenerated chemiluminescence (ECL) biosensor was developed on the basis of a closed bipolar electrode (BPE) apparatus for the analysis of prostate specific antigen (PSA). Bipolar modifications bring up two different stages of enhancement on the same electrode. Anodic enhancement was conducted by modifying gold nanoparticles (Au NPs) to catalyze the anodic ECL reaction between luminol and hydrogen peroxide. Cathodic introduction of thionine tagged PSA antibody led to a further pertinently enhancement synchronized with the PSA amount variation, because the existence of thionine greatly increased the rate of electron gains on cathode, leading to the corresponding acceleration of anodic ECL reaction. The more thionine modified target molecules were introduced, the faster luminol was oxidized, the higher faraday current approached, and sensitive quantification was realized in correlation with the responsive ECL intensity differences. The quantification resulted in a good determination range between 0.1pg/mL and 0.1µg/mL. This strategy mainly took advantage of the special structure of closed BPE to realize a simultaneous amplification on both ends of BPE. Moreover, the platform had a potential of providing a multi-functional strategy for the realization of other bio-detections by simply substituting the PSA sandwich structure with other bio-structures.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2016.03.059DOI Listing

Publication Analysis

Top Keywords

ecl biosensor
8
closed bipolar
8
anodic ecl
8
ecl reaction
8
ecl
5
psa
5
joint enhancement
4
enhancement strategy
4
strategy applied
4
applied ecl
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!