Pre-clinical and clinical data have unequivocally demonstrated the usefulness of decellularized heart valve (HV) matrices implanted for HV replacement therapy. However, human donor valves applicable for decellularization are in short supply, which prompts the search for suitable alternatives, such as porcine grafts. Since decellularization might be insufficient to remove all xenoantigens, we analysed the interaction of human preformed antibodies with decellularized porcine HV in vitro to assess potential immune reactions upon implantation. Detergent-decellularized pulmonary HV from German Landrace wild-type (wt) or α1,3-galactosyltransferase knockout (GGTA1-KO) pigs were investigated by inhibition ELISA and GSL I-B4 staining to localize and quantify matrix-bound αGal epitopes, which represent the most prominent xenoantigen. Additionally, preformed human xenoantibodies were affinity purified by perfusing porcine kidneys. Binding of purified human antibodies to decellularized HV was investigated by inhibition ELISA. Furthermore, binding of human plasma proteins to decellularized matrices was determined by western blot. Decellularized human pulmonary artery served as controls. Decellularization of wt HV led to a reduction of αGal epitopes by 70 %. Residual epitopes were associated with the subendothelial extracellular matrix. As expected, no αGal epitopes were found on decellularized GGTA1-KO matrix. The strongest binding of preformed human anti-pig antibodies was found on wt matrices, whereas GGTA1-KO matrices bound similar or even fewer xenoantibodies than human controls. These results demonstrate the suitability of GGTA1-KO pigs as donors for decellularized heart valves for human patients. Besides the presence of αGal antibodies on decellularized heart valves, no further preformed xenoantibodies against porcine matrix were detected in tested human sera.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00395-016-0560-7 | DOI Listing |
Cardiovasc Revasc Med
December 2024
Department of Cardiology and Catheterization Laboratories, Shonan Kamakura General Hospital, Okamoto 1370-1, Kamakura City, Kanagawa 247-8533, Japan. Electronic address:
Background/purpose: Transcatheter aortic valve replacement (TAVR) with ACURATE neo2 showed better hemodynamic outcomes by mitigating paravalvular leakage (PVL) compared with ACURATE neo, and revealed promising one-year outcomes in single-arm studies. However, studies comparing the hemodynamic and clinical outcomes of the two valves are still scarce. Therefore, this study aimed to compare the one-year hemodynamic and clinical outcomes between the neo2 and neo.
View Article and Find Full Text PDFJ Cardiovasc Dev Dis
December 2024
Faculty of Medicine & Health Sciences, University of Antwerp, 2610 Antwerp, Belgium.
The need for a permanent pacemaker (PPM) implantation after surgical aortic valve implantation (SAVR) is a recognized postoperative complication, with potentially long-term reduced survival. From 1987 to 2017, 2500 consecutive patients underwent SAVR with a biological valve with or without concomitant procedures such as CABG or mitral valve repair. Mechanical valves or valves in another position were excluded.
View Article and Find Full Text PDFAm J Transplant
December 2024
Department of Cardiovascular Surgery, Arkansas Children's Hospital, Little Rock, Arkansas. Electronic address:
Heart valve replacement in pediatric cardiothoracic surgery poses problems because conventional heart valve implants do not have the ability to grow. This mandates serial reoperations for implant exchanges until an adult size implant can fit. Partial heart transplantation eliminates these reoperations because the transplanted valves grow.
View Article and Find Full Text PDFJACC Cardiovasc Interv
December 2024
Department of Cardiology, The Heart Center, Copenhagen University Hospital Rigshospitalet, Copenhagen, Denmark.
Background: Survival after transcatheter aortic valve replacement (TAVR) has markedly increased. Thus, other comorbidities will intersect patient trajectories and challenge follow-up.
Objectives: The aim of this study was to describe patient characteristics and hospitalizations at end of life to further improve the quality of life for patients undergoing TAVR.
JACC Cardiovasc Interv
December 2024
Department of Cardiology, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; Center for Population Health Innovation, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Lübeck/Kiel, Lübeck, Germany; BG University Hospital Bergmannsheil, Bochum, Germany.
Background: Transradial secondary access (TR-SA) may serve as an alternative to the traditional femoral secondary access (TF-SA) for pigtail placement in transcatheter aortic valve replacement (TAVR).
Objectives: The aim of this study was to assess the incidence of secondary access-related vascular complications after TR-SA or TF-SA in TAVR.
Methods: The PULSE (Plug or sUture based vascuLar cloSurE after TAVR) registry retrospectively evaluated data of 10,120 patients who underwent transfemoral TAVR at 10 heart centers from 2016 to 2021.