Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Aim: To study the dose-response of stage I non-small-cell lung cancer (NSCLC) in terms of long-term local tumor control (LC) after conventional and hypofractionated photon radiotherapy, modeled with the linear-quadratic (LQ) and linear-quadratic-linear (LQ-L) approaches and to estimate the clinical α/β ratio within the LQ frame.
Material And Methods: We identified studies of curative radiotherapy as single treatment through MedLine search reporting 3-year LC as primary outcome of interest. Logistic models coupled with the biologically effective dose (BED) at isocenter and PTV edge according to both the LQ and LQ-L models with α/β = 10 Gy were fitted. Additionally, α/β was estimated from direct LQ fits.
Results: Thirty one studies were included reporting outcome of 2319 patients. The LQ-L fit yielded a significant value of 11.0 ± 5.2 Gy for the dose threshold (Dt) for BED10 at the isocenter. The LQ and LQ-L fits did not differ substantially. Concerning the estimation of α/β, the value obtained from the direct LQ fit for the complete fractionation range was 3.9 [68 % CI: 2.2-9.0] Gy (p > 0.05).
Conclusion: Both LQ and LQ-L fits can model local tumor control after conventionally and hypofractionated irradiation and are robust methods for predicting clinical effects. The observed dose-effect for local control in NSCLC is weaker at high doses due to data dispersion. For BED10 values of 100-150 Gy in ≥3 fractions, the differences in isoeffects predicted by both models can be neglected.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4859978 | PMC |
http://dx.doi.org/10.1186/s13014-016-0643-5 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!