Bright-Field Imaging and Optical Coherence Tomography of the Mouse Posterior Eye.

Methods Mol Biol

The Jackson Laboratory, 600 Main Street, Bar Harbor, ME, 04609, USA.

Published: December 2017

Noninvasive live imaging has been used extensively for ocular phenotyping in mouse vision research. Bright-field imaging and optical coherence tomography (OCT) are two methods that are particularly useful for assessing the posterior mouse eye (fundus), including the retina, retinal pigment epithelium, and choroid, and are widely applied due to the commercial availability of sophisticated instruments and software. Here, we provide a guide to using these approaches with an emphasis on post-acquisition image processing using Fiji, a bundled version of the Java-based public domain software ImageJ. A bright-field fundus imaging protocol is described for acquisition of multi-frame videos, followed by image registration to reduce motion artifacts, averaging to reduce noise, shading correction to compensate for uneven illumination, filtering to improve image detail, and rotation to adjust orientation. An OCT imaging protocol is described for acquiring replicate volume scans, with subsequent registration and averaging to yield three-dimensional datasets that show reduced motion artifacts and enhanced detail. The Fiji algorithms used in these protocols are designed for batch processing and are freely available. The image acquisition and processing approaches described here may facilitate quantitative phenotyping of the mouse eye in drug discovery, mutagenesis screening, and the functional cataloging of mouse genes by individual laboratories and large-scale projects, such as the Knockout Mouse Phenotyping Project and International Mouse Phenotyping Consortium.

Download full-text PDF

Source
http://dx.doi.org/10.1007/978-1-4939-3661-8_20DOI Listing

Publication Analysis

Top Keywords

bright-field imaging
8
imaging optical
8
optical coherence
8
coherence tomography
8
phenotyping mouse
8
mouse eye
8
imaging protocol
8
protocol described
8
motion artifacts
8
mouse phenotyping
8

Similar Publications

Transmission electron microscopy, especially at cryogenic temperature, is largely used for studying biological macromolecular complexes. A main difficulty of TEM imaging of biological samples is the weak amplitude contrasts due to electron diffusion on light elements that compose biological organisms. Achieving high-resolution reconstructions implies therefore the acquisition of a huge number of TEM micrographs followed by a time-consuming image analysis.

View Article and Find Full Text PDF

Magnetic field-dependent magnetization of highly crystalline FeO magnetic nanoparticles has been carried out to understand surface canting structures at low and room temperatures. The exchange bias () values of ∼18 to 27 Oe at 300 K for three samples prepared from different precursors are observed; and a decrease in value is obtained when the samples are measured at 5 K. However, with a decrease in temperature, coercivity () increases.

View Article and Find Full Text PDF

Deep learning-based morphometric analysis of zebrafish is widely utilized for non-destructively identifying abnormalities and diagnosing diseases. However, obtaining discriminative and continuous organ category decision boundaries poses a significant challenge by directly observing zebrafish larvae from the outside. To address this issue, this study simplifies the organ areas to polygons and focuses solely on the endpoint positioning.

View Article and Find Full Text PDF

Deep-learning-based image compression for microscopy images: An empirical study.

Biol Imaging

December 2024

Department of Biospectroscopy, Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Dortmund, Germany.

With the fast development of modern microscopes and bioimaging techniques, an unprecedentedly large amount of imaging data is being generated, stored, analyzed, and shared through networks. The size of the data poses great challenges for current data infrastructure. One common way to reduce the data size is by image compression.

View Article and Find Full Text PDF

Gram staining has been a frequently used staining protocol in microbiology. It is vulnerable to staining artifacts due to, e.g.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!