Introduction: Fialuridine (FIAU) is a nucleoside analog that is a substrate for bacterial thymidine kinase (TK). Once phosphorylated by TK, [(124)I]FIAU becomes trapped within bacteria and can be detected with positron emission tomography/computed tomography (PET/CT). [(124)I]FIAU PET/CT has been shown to detect bacteria in patients with musculoskeletal bacterial infections. Accurate diagnosis of prosthetic joint infections (PJIs) has proven challenging because of the lack of a well-validated reference. In the current study, we assessed biodistribution and dosimetry of [(124)I]FIAU, and investigated whether [(124)I]FIAU PET/CT can diagnose PJIs with acceptable accuracy.

Methods: To assess biodistribution and dosimetry, six subjects with suspected hip or knee PJI and six healthy subjects underwent serial PET/CT after being dosed with 74MBq (2mCi) [(124)I]FIAU intravenously (IV). Estimated radiation doses were calculated with the OLINDA/EXM software. To determine accuracy of [(124)I]FIAU, 22 subjects with suspected hip or knee PJI were scanned at 2-6 and 24-30h post IV injection of 185MBq (5mCi) [(124)I]FIAU. Images were interpreted by a single reader blinded to clinical information. Representative cases were reviewed by 3 additional readers. The utility of [(124)I]FIAU to detect PJIs was assessed based on the correlation of the patient's infection status with imaging results as determined by an independent adjudication board (IAB).

Results: The kidney, liver, spleen, and urinary bladder received the highest radiation doses of [(124)I]FIAU. The effective dose was 0.16 to 0.20mSv/MBq and doses to most organs ranged from 0.11 to 0.76mGy/MBq. PET image quality obtained from PJI patients was confounded by metal artifacts from the prostheses and pronounced FIAU uptake in muscle. Consequently, a correlation with infection status and imaging results could not be established.

Conclusions: [(124)I]FIAU was well-tolerated in healthy volunteers and subjects with suspected PJI, and had acceptable dosimetry. However, the utility of [(124)I]FIAU for the clinical detection of PJIs is limited by poor image quality and low specificity.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.nucmedbio.2016.01.004DOI Listing

Publication Analysis

Top Keywords

[124i]fiau
12
subjects suspected
12
prosthetic joint
8
[124i]fiau pet/ct
8
biodistribution dosimetry
8
suspected hip
8
hip knee
8
knee pji
8
radiation doses
8
utility [124i]fiau
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!