In this article, we have theoretically investigated the performance of graphene-hexagonal Boron Nitride (hBN) multilayer structure (hyper crystal) to demonstrate all angle negative refraction along with superior transmission. hBN, one of the latest natural hyperbolic materials, can be a very strong contender to form a hyper crystal with graphene due to its excellence as a graphene-compatible substrate. Although bare hBN can exhibit negative refraction, the transmission is generally low due to its high reflectivity. Whereas due to graphene's 2D nature and metallic characteristics in the frequency range where hBN behaves as a type-I hyperbolic material, we have found graphene-hBN hyper-crystals to exhibit all angle negative refraction with superior transmission. Interestingly, superior transmission from the whole structure can be fully controlled by the tunability of graphene without hampering the negative refraction originated mainly from hBN. We have also presented an effective medium description of the hyper crystal in the low-k limit and validated the proposed theory analytically and with full wave simulations. Along with the current extensive research on hybridization of graphene plasmon polaritons with (hyperbolic) hBN phonon polaritons, this work might have some substantial impact on this field of research and can be very useful in applications such as hyper-lensing.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4857181 | PMC |
http://dx.doi.org/10.1038/srep25442 | DOI Listing |
Cureus
December 2024
Cornea and Refractive Surgery, Al-Shifa Trust Eye Hospital, Rawalpindi, PAK.
Background: Glaucoma, particularly open-angle glaucoma (OAG), is a leading cause of irreversible blindness, associated with optic nerve damage, retinal ganglion cell death, and visual field defects. Corneal biomechanical properties and cellular components, such as corneal nerve and keratocyte densities assessed by in vivo confocal microscopy (IVCM), may serve as biomarkers for glaucoma progression. This study aimed to explore the relationship between corneal nerve parameters, keratocyte density, and optical coherence tomography (OCT)-derived retinal nerve fiber layer (RNFL) thickness in primary open-angle glaucoma (POAG) patients and controls.
View Article and Find Full Text PDFOphthalmic Physiol Opt
January 2025
Robert O Curle Ophthalmology Suite, Institute for Regeneration and Repair, The University of Edinburgh, Edinburgh, UK.
Purpose: To determine whether imaging features derived from fundus photographs contain 3D eye shape information beyond that available from spherical equivalent refraction (SER).
Methods: We analysed 99 eyes of 68 normal adults in the UK Biobank. An ellipsoid was fitted to the entire volume of each posterior eye (vitreous chamber without the lens)-segmented from magnetic resonance imaging of the brain.
Ophthalmic Physiol Opt
January 2025
Northeastern University College of Science, Boston, Massachusetts, USA.
Purpose: To assess longitudinal changes in optical quality across the periphery (horizontal meridian, 60°) in young children who are at high (HR) or low risk (LR) of developing myopia, as well as a small subgroup of children who developed myopia over a 3-year time frame.
Methods: Aberrations were measured every 6 months in 92 children with functional emmetropia at baseline. Children were classified into HR or LR based on baseline refractive error and parental myopia.
Int Ophthalmol
January 2025
Department of Ophthalmology, Faculty of Medicine, Hitit University, Çorum, Turkey.
Purpose: To examine the detailed vascular and morphological characteristics of the choroidal tissue in subjects with myopia.
Methods: A total of 111 subjects with myopia were included in the study. The study was conducted in three groups according to spherical equivalent(SE).
J Cataract Refract Surg
January 2025
Vision and Eye Research Institute, School of Medicine, Anglia Ruskin University, Cambridge, UK.
Purpose: To measure visual acuity at three different defocus planes in pseudophakic subjects with varying levels of spherical aberration induced by an adaptive optics visual simulator. The study aimed to simulate Extended Depth of Focus (EDOF) intraocular lenses (IOLs).
Setting: Private hospital (IMO, Barcelona, Spain).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!