Purpose: It is questionable how much of the PCL is really preserved following a complete transverse tibial cut during a cruciate-retaining (CR) total knee arthroplasty (TKA). It is hypothesized that a complete transverse tibial cut jeopardizes the PCL tibial insertion during a common CR TKA. Thus, the aim of the present study was to assess intraoperatively the amount of PCL tibial attachment damage following a standard complete tibial cut technique.

Methods: Thirty consecutive female patients suffering from degenerative knee osteoarthritis were included. Two measurements were performed on preoperative MRI images. On sagittal plane, the PCL facet of tibia and the PCL tibial attachment were measured. All 30 patients underwent a TKA using a common CR prosthesis. Postoperatively, the amount of PCL facet resection was measured on the resected tibial plateau using a digital sliding caliper.

Results: In preoperative MRI images, the length of the PCL facet of tibia was found 25.5 ± 2.1 mm and the length of the PCL tibial attachment was 14.5 ± 1.3 mm. The amount of PCL facet resection following TKA was 20.6 ± 2.2 mm on average. This result corresponds to an average resection of 65.1 ± 15.9 % of the PCL tibial attachment following TKA.

Conclusion: The hypothesis that a complete transverse tibial cut during a conventional CR TKA jeopardizes the PCL tibial insertion was confirmed. According to measurements performed on preoperative knee MRI scans and surgical specimens of resected tibial plateaus, a significant amount of the PCL insertion on the tibia is actually removed in the majority of cases. Surgeons should be aware that when resecting the tibial plateau without using a technique that spares the PCL tibial attachment, there is a high risk of considerable damage to the PCL that may, in turn, increase the likelihood of potential complications due to PCL deficiency.

Level Of Evidence: IV.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00167-016-4144-8DOI Listing

Publication Analysis

Top Keywords

pcl tibial
28
tibial attachment
20
pcl
16
tibial cut
16
amount pcl
16
pcl facet
16
tibial
14
complete transverse
12
transverse tibial
12
cruciate-retaining total
8

Similar Publications

3D-printed TiC/polycaprolactone composite scaffold with a DOPA-SDF1 surface modified for bone repair.

Colloids Surf B Biointerfaces

December 2024

Department of Orthopaedic Surgery, Orthopaedic Center, The First Hospital of Jilin University, Changchun 130021, China. Electronic address:

Large bone defects are a major clinical challenge in bone reconstructive surgery. 3D printing is a powerful technology that enables the manufacture of custom tissue-engineered scaffolds for bone regeneration. Electrical stimulation (ES) is a treatment method for external bone defects that compensates for damaged internal electrical signals and stimulates cell proliferation and differentiation.

View Article and Find Full Text PDF

Superior One-year Forgotten Joint Scores with cruciate-retaining mobile bearings versus posterior-stabilized mobile and fixed bearings in a contemporary total knee system.

Knee

December 2024

Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, South Korea; Department of Orthopaedic Surgery, Seoul National University Hospital, Seoul, South Korea. Electronic address:

Background: Total knee arthroplasty (TKA) mainly involves the femoral, tibial, and bearing implants. Bearings are categorized by posterior cruciate ligament (PCL) status (cruciate-retaining [CR] vs. posterior-stabilized [PS]) and motion (mobile vs.

View Article and Find Full Text PDF

Background And Purpose:  In total knee arthroplasty (TKA), an insert with ball-in-socket (BS) medial conformity (MC) and posterior cruciate ligament (PCL) retention restores kinematics closer to native than an insert with intermediate (I) MC. However, high medial conformity might compromise baseplate stability as indicated by maximum total point motion (MTPM). Using the BS MC insert with PCL retention, we aimed to determine whether (i) the baseplate is stable as indicated by mean MTPM < 0.

View Article and Find Full Text PDF

Background: Injury to the posterior vasculature is a potential complication in orthopaedic knee surgery that may be associated with variations in its anatomy, such as the type II-A2 variant, which places the anterior tibial artery (ATA) in closer proximity to the tibia. However, how close surgical instrumentation comes to injuring the ATA is not well described.

Purpose: To determine how the type II-A2 variant of the popliteal vasculature affects proximity of the ATA to instrumentation for orthopaedic knee procedures.

View Article and Find Full Text PDF

Purpose: The failure rate following posterolateral corner reconstruction (PLC) remains high. Previous research indicates that in posterior cruciate ligament (PCL) reconstruction the laxity is affected by the tibial slope (TS). However, there is currently no literature evaluating the impact of TS on surgical outcome in combined reconstruction of PLC/PCL.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!