Purpose: The current and projected shortage of transplantable human donor corneas has prompted the development of long-term alternatives to human donor tissue for corneal replacement. The biosynthetic stromal substitutes (BSS) characterized herein represent a potentially safe alternative to donor organ transplantation for anterior corneal stromal diseases. The goal of this phase 1 safety study was to characterize the three-dimensional (3D) corneal shape of the first 10 human patients implanted with a BSS and assess its stability over time.
Methods: Ten patients underwent anterior lamellar keratoplasty using a biosynthetic corneal stromal implant for either advanced keratoconus or central corneal scarring. Surgeries were performed at Linköping University Hospital, between October and November 2007. Serial corneal topographies were performed on all eyes up to a 4-year follow-up when possible. Three-dimensional shape average maps were constructed for the 10 BSS corneas and for 10 healthy controls. Average 3D shape corneal elevation maps, difference maps, and statistics maps were generated.
Results: The biosynthetic stromal substitutes implants remained stably integrated into the host corneas over the 4-year follow-up period, without signs of wound dehiscence or implant extrusion. The biosynthetic stromal substitutes corneas showed steeper surface curvatures and were more irregular than the healthy controls.
Conclusions: Corneal astigmatism and surface steepness were observed 4 years after BSS implantation, while the implants remained stably integrated in the host corneas. Future studies will indicate if biomaterials technology will allow for the optimization of postoperative surface irregularity after anterior stromal replacement, a new window of opportunity that is not available with traditional corneal transplantation techniques.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1167/iovs.15-18271 | DOI Listing |
Ocul Surf
January 2025
Department of Ophthalmology, Visual and Anatomical Sciences, Wayne State University School of Medicine, Detroit, MI. Electronic address:
Purpose: To ascertain the homing of monocytes and neutrophils in the epithelium versus stroma of HSV-1 infected corneas at different stages of infection and functional significance of their anatomical location in virus-infected corneas.
Methods: The corneas of C57BL/6J mice were infected with HSV-1 McKrae. Mice were euthanized on different days post-infection.
Invest Ophthalmol Vis Sci
January 2025
Harry S. Truman Memorial Veterans' Hospital, Columbia, Missouri, United States.
Purpose: Sulfur mustard gas (SM) exposure to eyes causes multiple corneal injuries including stromal cell loss in vivo. However, mechanisms mediating stromal cell loss/death remains elusive. This study sought to test the novel hypothesis that SM-induced toxicity to human corneal stromal fibroblasts involves ferroptosis mechanism via p38 MAPK signaling.
View Article and Find Full Text PDFCornea
January 2025
Eyejun Ophthalmic Clinic, Seoul, Republic of Korea; and.
Purpose: To investigate the efficacy and safety of secondary surgical intervention of combined phototherapeutic keratectomy (PTK) with alcohol delamination and peripheral anterior stromal puncture (ASP) for refractory recurrent corneal erosion (RCE).
Methods: This retrospective comparative study defined refractory RCE as cases persisting for more than 6 months after primary surgical intervention. A total of 115 eyes from 115 patients with refractory RCE, treated either with (n = 92) or without (n = 23) the secondary surgical treatment combining PTK and ASP between January 2021 and January 2023, were included.
Purpose: To evaluate the clinical outcome of laser-assisted surgical correction of high hyperopic or mixed astigmatism using small incision intrastromal lenticule rotation (SMILERO) alone or combined with photorefractive keratectomy (PRK).
Methods: This retrospective case series enrolled 25 eyes with high astigmatism that underwent SMILERO surgery. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), manifest refraction, central corneal thickness, and corneal higher order aberrations were analyzed before surgery and after 3, 6, and 12 months of follow-up.
J Ophthalmic Inflamm Infect
January 2025
Department of Ophthalmology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan.
Purpose: Corynebacterium species are commensals of human skin and mucous membranes and are recognized as important pathogens in ocular infections. This study investigated the clinical characteristics of Corynebacterium keratitis.
Methods: We retrospectively reviewed cases of bacterial keratitis in which Corynebacterium species were solely isolated from corneal scraping cultures collected at Ehime University Hospital between January 2010 and February 2024.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!