[Purpose] The purpose of this study was to analyze test-retest reliability of an active range of motion test using a manual goniometer by unskilled examiners. [Subjects and Methods] Active range of motion was measured in 30 students attending U university (4 males, 26 females). Range of motion during flexion and extension of the shoulder and hip joints were measured using a manual goniometer. [Results] Flexion and extension of the shoulder joint (ICC=0.906 and ICC=0.808) and (ICC=0.946 and ICC=0. 955) of the hip joint showed excellent reliabilities. [Conclusion] The active range of motion test using a manual goniometer showed very high test-retest reliability in unskilled examiners. When examiners are aware of the method of the test, an objective assessment can be conducted.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4842428 | PMC |
http://dx.doi.org/10.1589/jpts.28.722 | DOI Listing |
Arch Orthop Trauma Surg
January 2025
UT Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA.
Introduction: Manipulation under anesthesia (MUA) is a standard and effective treatment to correct stiffness and improve range of motion (ROM) following total knee arthroplasty (TKA). Delayed MUA has been associated with increased rates of revision surgeries and infections. Early MUA has been shown to double the mean gain in flexion compared to delayed interventions.
View Article and Find Full Text PDFArch Orthop Trauma Surg
January 2025
Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland.
Total hip arthroplasty (THA) is a very successful operation. Once the problem of implant fixation was solved with the use of bone cement, the next development steps focused on improving the bearing. Weber, a Swiss surgeon, introduced the first modular heads in THA.
View Article and Find Full Text PDFOper Orthop Traumatol
January 2025
Klinik für Orthopädie und Unfallchirurgie, Martin-Luther-Krankenhaus Berlin, Caspar-Theyss-Str. 27-33, 14193, Berlin, Deutschland.
Objective: Lengthening of the patellar tendon to normalize patellar height and improve knee flexion deficits.
Indications: Flexion deficits in combination with patella baja (Caton index < 0.6).
Arch Orthop Trauma Surg
January 2025
Department of Orthopaedic Surgery, University Hospital centre (Saint Etienne), Avenue Albert Raimond, Saint-priest-en-Jarez, 42270, France.
Introduction: Total knee arthroplasty (TKA) in valgus knees is challenging. Optimal ligament balance, implant neutral or moderate valgus alignment are crucial but conventional instrumentations usually lead to outliers. Robotic arm assisted TKA (RATKA) advantages could answer this challenge.
View Article and Find Full Text PDFObjective: To evaluate the short-term clinical efficacy of external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures (AO-23C type), based on the principles of Chinese osteosynthesis (CO).
Methods: Forty-eight patients with unstable distal radius fractures between January 2022 and February 2023 were retrospectively analyzed and divided into the CO external fixation group and internal fixation group. CO external fixation group consisted of 25 patients, including 7 males and 18 females, aged from 37 to 56 years old with an average of ( 52.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!