We present a new core needle biopsy and treatment electrode precision placement technique which, regardless of needle size, target lesion hardness and elasticity, makes it possible to precisely place an image guided device inside the abnormal tissue. Once inside the abnormal lesion, multiple tissue samples can be collected using a dedicated trocar and collecting system. Our unique "Fourier" driver substitutes the commonly used spring-loaded device or complements the jerky insertion technique used by experienced interventional physicians. It enables the physician to precisely and with extreme tactility maneuver even large diameter core needles or treatment-electrodes into the lesion using only a diminutive external force. This is achieved by applying supporting servo-controlled mechanical high-acceleration micro-pulses, proportional to the average vector directed by the physician. The Fourier-needle or Fourier-electrode stands completely non-moving when the system automatically goes into full idling. This means that the angle of attack successively and arbitrary can be aligned to hit the target, becoming successively symmetrically inserted into even small tumors to be treated as well as exactly hit any point outlined by real time ultrasound guiding. This kind of biopsy needle or treatment electrode placement results in a uniquely accurate and less traumatic procedure. Due to the risk of disseminating viable tumor cells the precision placement device can be combined with a computer controlled anti-seeding system, denaturizing tumor cells detached during penetration of the biopsy needle or treatment electrode.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ejmp.2016.04.007 | DOI Listing |
Polymers (Basel)
January 2025
Research School of Chemical and Biomedical Technologies, Tomsk Polytechnic University, Lenin Ave. 30, 634050 Tomsk, Russia.
Laser reduction of graphene oxide (GO) is a promising approach for achieving flexible, robust, and electrically conductive graphene/polymer composites. Resulting composite materials show significant technological potential for energy storage, sensing, and bioelectronics. However, in the case of insulating polymers, the properties of electrodes show severely limited performance.
View Article and Find Full Text PDFJ Clin Med
January 2025
Gastroenterology and Digestive Endoscopy Unit, Forlì-Cesena Hospitals, 47121 Romagna, Italy.
Endoscopic ultrasound (EUS)-guided radiofrequency ablation (RFA) is a promising minimally invasive technique for the treatment of pancreatic lesions. This review first focuses on the technical aspects in EUS-RFA: the procedure typically employs EUS probes with integrated radiofrequency electrodes, enabling accurate targeting and ablation of pancreatic lesions. Different types of RFA devices, monopolar and bipolar energy delivery systems, are discussed, along with considerations for optimal ablation, including energy settings, procedure time, and pre- and post-procedural management.
View Article and Find Full Text PDFMaterials (Basel)
January 2025
King Abdulaziz City for Science and Technology (KACST), Microelectronics and Semiconductors Institute, Mailbox 6086, Riyadh 11442, Saudi Arabia.
With growing environmental concerns and the need for sustainable energy, multifunctional materials that can simultaneously address water treatment and clean energy production are in high demand. In this study, we developed a cost-effective method to synthesize zinc oxide (ZnO) nanowires via the anodic oxidation of zinc foil. By carefully controlling the anodization time, we optimized the Zn/ZnO-5 min electrode to achieve impressive dual-function performance in terms of effective photoelectrocatalysis for water splitting and waste water treatment.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Anaesthesiology Service, Pain Unit, Complejo Asistencial Universitario de Salamanca (CAUSA), 37007 Salamanca, Spain.
: The International Society for Modulation defines persistent spinal pain syndrome type 2 (PSPS-type 2), formerly known as failed back surgery syndrome, as a condition where patients continue to experience pain or develop new pain following spinal surgery intended to alleviate back or lower-limb discomfort. PSPS-type 2 is characterized by pain and significant disability, affecting quality of life. Spinal cord stimulation has proven effective in treating this syndrome, although the role of psychological factors, such as pain catastrophizing and central sensitization, remain unclear.
View Article and Find Full Text PDFMedicina (Kaunas)
December 2024
Heart Center Hirslanden Zurich, 8008 Zurich, Switzerland.
: This study aims to examine the success of concomitant surgical ablation in patients with atrial fibrillation after one, three, and five years. Additionally, important predictors for rhythm outcome and rates of permanent pacemaker implantations were analyzed. : In this retrospective study, we included patients who were referred to the University Hospital of Basel, Switzerland, between 2011 and 2017.