A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Importance of vial shape and type on the reproducibility of size exclusion chromatography measurement of monoclonal antibodies. | LitMetric

Importance of vial shape and type on the reproducibility of size exclusion chromatography measurement of monoclonal antibodies.

J Chromatogr B Analyt Technol Biomed Life Sci

School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Boulevard d'Yvoy 20, 1211 Geneva 4, Switzerland. Electronic address:

Published: October 2016

The goal of this work is to understand the phenomenon behind the poor injection repeatability often observed with protein biopharmaceuticals. All the measurements were carried out in size exclusion chromatography (SEC) mode, using fifteen commercially available therapeutic monoclonal antibodies (mAbs). First of all, we proved that the variation of peak areas between consecutive injections was much more critical with highly concentrated mAb samples (up to 80mg/mL), while the SEC measurements of commercial mAbs having concentrations below 5mg/mL were reliable. Second, we emphasized that the shapes, volumes and materials of the sample vial insert also contribute to the change of peak areas observed during consecutive injections. In this study, six different insert models were studied and the most critical were the ones possessing the narrowest conical shape at the bottom. Furthermore, the homogenization of samples (with pipette mixing rather than vortex) prior to analysis was of great interest and allows a significant improvement in injection repeatability. Finally, because the on-wall (on-insert) adsorption of mAbs reaches its equilibrium in around 50min, it is advised to add a specified residence time prior to injection to achieve repeatable injection.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2016.04.032DOI Listing

Publication Analysis

Top Keywords

size exclusion
8
exclusion chromatography
8
monoclonal antibodies
8
injection repeatability
8
peak areas
8
consecutive injections
8
vial shape
4
shape type
4
type reproducibility
4
reproducibility size
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!