This paper deals with the development of hydrophilic interaction liquid chromatographic (HILIC) method for the analysis of bilastine and its degradation impurities following Analytical Quality by Design approach. It is the first time that the method for bilastine and its impurities is proposed. The main objective was to identify the conditions where an adequate separation in minimal analysis duration could be achieved within a robust region. Critical process parameters which have the most influence on method performance were defined as acetonitrile content in the mobile phase, pH of the aqueous phase and ammonium acetate concentration in the aqueous phase. Box-Behnken design was applied for establishing a relationship between critical process parameters and critical quality attributes. The defined mathematical models and Monte Carlo simulations were used to identify the design space. Fractional factorial design was applied for experimental robustness testing and the method is validated to verify the adequacy of selected optimal conditions: the analytical column Luna(®) HILIC (100mm×4.6mm, 5μm particle size); mobile phase consisted of acetonitrile-aqueous phase (50mM ammonium acetate, pH adjusted to 5.3 with glacial acetic acid) (90.5:9.5, v/v); column temperature 30°C, mobile phase flow rate 1mLmin(-1), wavelength of detection 275nm.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2016.04.022DOI Listing

Publication Analysis

Top Keywords

mobile phase
12
analytical quality
8
quality design
8
bilastine degradation
8
degradation impurities
8
hydrophilic interaction
8
interaction liquid
8
liquid chromatographic
8
critical process
8
process parameters
8

Similar Publications

Problem: To address the long waiting times patients incur when visiting outpatient departments in India.

Approach: In 2022, the National Health Authority in India developed a paperless service, called Scan and Share, leveraging mobile technology and QR (quick-response) codes to streamline outpatient department appointments. Patients can use a mobile application (app) to scan QR codes at health facilities, generating tokens linked to registration counters.

View Article and Find Full Text PDF

Expanding the chemical coverage of polar compounds in water analysis by coupling supercritical fluid with hydrophilic interaction chromatography high-resolution mass spectrometry.

Anal Chim Acta

March 2025

Van't Hoff Institute for Molecular Sciences (HIMS), University of Amsterdam, Science Park 904, 1098 XH, Amsterdam, the Netherlands; Centre for Analytical Sciences Amsterdam, Science Park 904, 1098 XH, Amsterdam, the Netherlands. Electronic address:

Background: Persistent and mobile organic compounds (PMOC) are of great concern for water quality and human health. The recent improvement and availability of high-resolution mass spectrometry in combination with liquid chromatography have widely expanded the potential of analytical workflows for their detection and quantitation in water. Given their high polarity, the detection of some PMOC requires alternative techniques to reversed-phase chromatography, such as hydrophilic interaction liquid chromatography (HILIC) and supercritical fluid chromatography (SFC).

View Article and Find Full Text PDF

Experimental and computational analysis of lipophilicity and plasma protein binding properties of potent tacrine based cholinesterase inhibitors.

J Chromatogr B Analyt Technol Biomed Life Sci

January 2025

University of Belgrade-Institute of Chemistry, Technology and Metallurgy, Department of Chemistry, Njegoševa 12, 11000 Belgrade, Republic of Serbia. Electronic address:

The lipophilicity of thirteen tacrine/piperidine-4-carboxamide derivatives was assessed using reversed-phase thin-layer chromatography (RP-TLC) with MeOH and acetonitrile (ACN) as organic modifiers. Among the parameters evaluated, the R and C values obtained using MeOH were identified as the most reliable for characterizing the lipophilicity of the investigated compounds. The observed differences in lipophilicity among the derivatives resulted from a delicate interplay of substituent effects (hydrophobicity, polarity, steric hindrance, and electronic effects), positional influence, and characteristics of the organic modifier.

View Article and Find Full Text PDF

Exploring the Credibility of Large Language Models for Mental Health Support: Protocol for a Scoping Review.

JMIR Res Protoc

January 2025

Data and Web Science Group, School of Business Informatics and Mathematics, University of Manneim, Mannheim, Germany.

Background: The rapid evolution of large language models (LLMs), such as Bidirectional Encoder Representations from Transformers (BERT; Google) and GPT (OpenAI), has introduced significant advancements in natural language processing. These models are increasingly integrated into various applications, including mental health support. However, the credibility of LLMs in providing reliable and explainable mental health information and support remains underexplored.

View Article and Find Full Text PDF

Dual Open Atom Interferometry for Compact and Mobile Quantum Sensing.

Phys Rev Lett

December 2024

The Australian National University, Department of Quantum Science and Technology, Canberra, Australian Capital Territory 2601, Australia.

We demonstrate an atom interferometer measurement protocol compatible with operation on a dynamic platform. Our method employs two open interferometers, derived from the same atomic source, with different interrogation times to eliminate initial velocity dependence while retaining precision, accuracy, and long term stability. We validate the protocol by measuring gravitational tides, achieving a precision of 4.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!