The aim of this study was to assess the presence, location and, multiplanar distance of the canalis sinuosus (CS) between the incisive foramen and the anterior maxillary alveolar ridge using cone beam computed tomography (CBCT). Therefore, 500 CBCT maxillary images obtained from male and female patients aged 20 to 80 years were selected to assist in the dental treatment. Low-quality tomographic images were discarded. All images were captured with the i-CATTM Classic tomograph and assessed using the XoranCatTM software. The axial sections were analyzed at the incisive foramen in order to verify the CS presence in laterality and location. Furthermore, linear measurements of the nasal cavity floor, buccal cortical bone, and alveolar ridge crest were made. All the collected data were statistically analyzed. Results show a variation of the CS in relation to the classification and distance of anatomical structures, but no significant difference between the right and left sides. It should be highlighted that CBCT is necessary before invasive procedures in order to preserve important anatomical structures. In conclusion, the location of the CS varies in relation to the alveolar ridge crest and buccal cortical bone, assuming that it is going to be located by the upper lateral incisor palatine.

Download full-text PDF

Source
http://dx.doi.org/10.1590/1807-3107BOR-2016.vol30.0049DOI Listing

Publication Analysis

Top Keywords

alveolar ridge
12
canalis sinuosus
8
cone beam
8
beam computed
8
computed tomography
8
incisive foramen
8
buccal cortical
8
cortical bone
8
ridge crest
8
anatomical structures
8

Similar Publications

The objective of this study was to tailor an osteoinductive scaffold for alveolar bone regeneration and around immediately placed implants in extraction sockets of dogs. Tailored amorphous multiporous bioactive glass (TAMP -BG) was prepared and characterized for bioactivity and response of human alveolar bone marrow mesenchymal stem cells (hABMSCs). Extraction sockets of twenty-two male mongrel dogs received TAMP-BG in the right side around implant in the distal socket of the mandibular fourth premolar (P4), while the adjacent empty mesial socket of the same tooth was filled with the same graft.

View Article and Find Full Text PDF

Background: Paracoccidioidomycosis (PCM) is a systemic mycosis endemic and limited to Latin America. Brazil is responsible for more than 80% of diagnosed cases in the world. Since PCM is not a notifiable disease, there are still no accurate data on its incidence in Brazil.

View Article and Find Full Text PDF

Imaging of Pulmonary Vasculitis.

Radiol Clin North Am

March 2025

Cardiopulmonary Imaging Section, Department of Radiology, University of Alabama at Birmingham, JTN 361, 619 19th Street South, Birmingham, AL 35294, USA. Electronic address:

This review will describe various disease processes resulting in pulmonary vasculitis. The clinical and imaging findings in these diseases often overlap with diffuse alveolar hemorrhage secondary to pulmonary capillaritis, a common manifestation in many of these diseases. A multidisciplinary approach is important for the correct diagnosis of these diseases, and this review will highlight the important imaging findings that radiologists need to be aware of to aid in this diagnostic process.

View Article and Find Full Text PDF

Pathology of Pulmonary Vascular Disease with Radiologic Correlation.

Radiol Clin North Am

March 2025

Department of Pathology and Laboratory Medicine, University of Wisconsin, Madison, WI, USA. Electronic address:

Pulmonary hypertensive changes are commonly seen by the surgical pathologist, but the majority represents secondary changes due to some process extrinsic to the lung. Some primary, or idiopathic, vascular diseases result in unique pathologic changes including the plexiform lesion and venous hypertensive changes. Thromboembolic disease also shows unique pathologic features.

View Article and Find Full Text PDF

Light-polymerizing reline materials offer improved chairside workability compared to conventional auto-polymerizing reline materials, addressing the partial denture (RPD) incompatibility caused by residual ridge resorption owing to long-term use. This study evaluates the fitting accuracy of relined materials by combining conventional fitting tests with three-dimensional (3D) measurements for detailed analysis. Light-polymerizing reline material (HikariLiner, Tokuyama, Tokyo, Japan, LP) and auto-polymerizing material (Rebase III, Tokuyama, AP) were used.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!