Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To investigate the patterns of changes in serum levels of of D-dimer, fibrinogen (FIB) and fibrin degradation product (FDP) during catheter-directed thrombolysis (CDT) in patients with acute lower-extremity deep venous thrombosis (DVT) and explore their clinical significance.
Methods: From June, 2014 to June, 2015, 50 patients with acute lower-extremity DVT received CDT. The serum concentrations of D-dimer, FIB and FDP were measured before, during and after CDT in all the subjects, with 50 healthy subjects serving as the control group.
Results: Compared with the control group, the patients in DVT group showed significantly increased serum levels of D-dimer (29.17±38.67 vs 0.21 ±0.27 µg/mL), FIB (3.66±0.95 vs 3.32±0.65 g/L) and FDP (76.14±131.48 vs 1.08±0.73 µg/mL) before CDT (P<0.05). Based on the effect of CDT, the patients with DVT were divided into recanalization group (n=34) and failed recanalization group (n=16), and the patients with recanalization had significantly increased serum concentration of D-dimer and FDP (P<0.05) and decreased FIB level (P<0.05) compared with those with failed recanalization at 24 h of CDT. D-dimer, FDP, and FIB showed no significant changes in the patients with failed recanalization after the procedure (P>0.05). Correlation analysis showed that serum D-dimer (r=0.66, P<0.05) and FDP (r=0.50, P<0.05) at 24 h of the procedure were positively correlated with the outcomes of CDT.
Conclusion: Serum levels of D-dimer, FIB and FDP are important indicators for evaluating and predicting the effectiveness of CDT in patients with acute DVT.