Background: In reoperation of femoral prostheses, there is a higher percentage of complications associated with the extraction of bone cement from the femoral channel, which is technically and time consumingly tedious. Shockwaves have been used in medicine for years, particularly in urology for the destruction of concretions and orthopaedics, as a method of treating pain in patients with calcifying enthesopathy.

Materials And Methods: We studied the use of shockwaves generated by a new source based on the multichannel discharge principle in facilitating extraction of bone cement. Femurs of experimental minipigs were chosen as models. We implanted bone cement into the femoral channel and subsequently applied shockwaves. We then measured the force necessary to extract bone cement.

Results: The results indicate that the force necessary for extracting cement was consistently statistically significantly lower in the group treated with multichannel discharge shockwaves compared to that for the controls.

Download full-text PDF

Source

Publication Analysis

Top Keywords

bone cement
16
multichannel discharge
12
extraction bone
8
cement femoral
8
femoral channel
8
bone
6
cement
5
model action
4
action shockwave
4
shockwave generated
4

Similar Publications

Study Design: Multicenter retrospective cohort study.

Objective: To evaluate the efficacy and safety of using cement-augmented pedicle screw (CAPS) fixation only for the cephalad and caudal vertebral bodies.

Summary Of Background Data: Pedicle screw fixation is less effective in patients with low-quality bone.

View Article and Find Full Text PDF

A hybrid coating made of poly (methyl methacrylate) with SiO2-TiO2 particles (PMMA/SiO2-TiO2) has been developed for use as a coating on nanosatellites, evaluating its resistance to high vacuum by quantifying its weight loss. The coating was applied on an Al 7075 aluminum substrate used for the aerospace sector. PMMA/SiO2-TiO2 hybrid coatings were prepared using sol-gel reaction in situ assisted with sonochemistry.

View Article and Find Full Text PDF

This in vitro study aims to evaluate various surface treatments on the shear bond strength and failure mode of CAD/CAM PMMA teeth to the heat-polymerized acrylic denture base. The study sample consisted of 100 teeth that were divided equally into five groups: Group 1: denture artificial teeth (control), Group 2: PMMA teeth without surface treatment, Group 3: PMMA teeth with MMA etching, Group 4: PMMA teeth with sandblasting (aluminum oxide particles), and Group 5: PMMA teeth with perpendicular grooves. The shear bond strength test was performed using a universal testing machine and the failure mode was recorded.

View Article and Find Full Text PDF

Background: The pelvis is one of the most common areas for metastatic bone disease. We recently described the use of a minimally invasive percutaneous screw fixation of metastatic non-periacetabular pelvic lesions, with excellent results.

Description: The procedure can be completed in a standard operating theater without the need for special instruments.

View Article and Find Full Text PDF

To exclusively evaluate, in vitro, the efficacy of five intracanal medicaments against Candida albicans and Enterococcus faecalis in infected single-rooted primary teeth. Forty-three teeth were selected, out of which 42 were simultaneously contaminated with C. albicans and E.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!