Introduction: Analytical morphomics focuses on extracting objective and quantifiable data from clinical computed tomography (CT) scans to measure patients' frailty. Studies are currently retrospective in nature; therefore, it would be beneficial to develop animal models for well-controlled, prospective studies. The aim of this study is to develop an in vivo microCT protocol for the longitudinal acquisition of whole-body images suitable for morphomic analyses of bone.
Methods: The authors performed phantom studies on 2 microCT systems (Inveon and CT120) to study tissue radiodensity and further characterize system performance for collecting animal data. The authors also describe their design of a phantom-immobilization device using phantoms and an ovariectomized (OVX) mouse.
Results: The authors discovered increased consistency along the z-axis for scans acquired on the Inveon compared with CT120, and calibration by individual slice reduces variability. Objects in the field of view had more impact on measurement acquired using the CT120 compared with the Inveon. The authors also found that using the middle 80% of slices for data analysis further decreased variability, on both systems. Moreover, bone-mineral-density calibration using the QCT Pro Mini phantom improved bone-mineral-density estimates across energy spectra, which helped confirm our technique. Comparison of weekly body weights and terminal uterine mass between sham and OVX groups validated our model.
Discussion: The authors present a refined microCT protocol to collect reliable and objective data. This data will be used to establish a platform for research animal morphomics that can be used to test hypotheses developed from clinical human morphomics.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/SCS.0000000000002574 | DOI Listing |
J Comp Neurol
January 2025
School of Natural Sciences, Macquarie University, Sydney, New South Wales, Australia.
Recent advances in microCT are facilitating the investigation of microstructures in spiders and insects leading to an increased number of studies investigating their neuroanatomy. Although microCT is a powerful tool, its effectiveness depends on appropriate tissue preparation and scan settings, particularly for soft, non-sclerotized tissues, such as muscles, organs, and neural tissues. As the application of microCT in spiders is only in its infancy, published protocols are often difficult to implement due to substantial size variation of the specimens.
View Article and Find Full Text PDFJ Endod
January 2025
Faculdade São Leopoldo Mandic, Instituto de Pesquisa São Leopoldo Mandic, Área de Endodontia, Campinas, São Paulo, Brasil.
Introduction: This study evaluated the shaping ability of the single-file XP-endo Shaper (XP-S) system, employing an extended working time, and the Reciproc Blue #40/.06 (REC) instrument during the preparation of oval-shaped canals.
Methods: Eleven pairs of contralateral premolars with a single canal were divided into two groups (n = 11) according to the canal preparation protocol: XP-S (with an additional 45 seconds of instrumentation) and REC.
Calcif Tissue Int
January 2025
Research Centre in Physical Activity, Health and Leisure (CIAFEL), Faculty of Sport, University of Porto, (FADEUP), Rua Dr. Plácido Costa 91, 4200-450, Porto, Portugal.
Swimming is a popular sport with several health benefits, but its effects on bone quality are controversial possibly due to distinct effects on different anatomical regions. Our aim was to investigate the effect of 8-month swimming on bone growth, mass, geometry, trabecular microarchitecture and osteocyte density of the lumbar vertebrae, femur and tibia of male rats. Wistar rat models were assigned to either a swimming (n = 10; 2h/d, 5 d/week) or a physically active control group (n = 10) for 8 months, after which they were sacrificed and their lumbar vertebrae, femur and tibia assessed for bone mass, cortical geometry, trabecular microarchitecture and osteocyte density through µ-CT and histology.
View Article and Find Full Text PDFBMC Oral Health
January 2025
Faculty of Dentistry, Basic Medical Sciences Department, Ankara University, Ankara, 06560, Turkey.
Background: This study aimed to comparatively evaluate the effects of different cavity conditioners on internal adaptation (IA) of glass ionomer-based restorative materials applied to primary teeth.
Methods: 80 extracted primary second molar teeth were randomly assigned to four different cavity conditioner groups [10% polyacrylic acid, 20% polyacrylic acid, 17% ethylene diamine tetraacetic acid (EDTA), 35% phosphoric acid]. Class V cavities were prepared on the buccal surfaces and relevant cavity conditioners were applied, and the samples in each cavity conditioner group were randomly assigned to glass hybrid (GHR) or conventional glass ionomer restoratives (CGIR).
BMC Oral Health
January 2025
Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, Nanjing, China.
Objectives: To compare the stress distribution and crack propagation in cracked mandibular first molar restored with onlay, overlay, and two types of occlusal veneers using two different CAD/CAM materials by Finite Element Analysis (FEA).
Materials And Methods: A mandibular first molar was digitized using a micro CT scanning system in 2023. Three-dimensional dynamic scan data were transformed, and a 3D model of a cracked tooth was generated.