The aim of the study was to assess pH, pO2 and pCO2 in peritoneal fluid. The study was conducted on a group of 22 dogs with symptoms of ascites. Group 1 consisted of 4 dogs with adenocarcinoma, group 2--of 6 dogs with glomerulonephritis, group 3 of 8 dogs with hepatic cirrhosis and group 4 of 4 dogs with bacterial peritonitis. An abdominal cavity puncture was performed in all dogs and the fluid was drawn into a heparinized syringe in order to assess pH, pO2 and pCO2 . The analysis of pH in the peritoneal fluid revealed statistically significant differences between group 4 and groups 1 (p=0.01), 2 (p=0.01), and 3 (p=0.01). The lowest pH value compared to the other studied groups was recorded in group 4. In group 4, the pO2 was the lowest compared to the other groups (group 1 p=0.01, group 2 p=0.01, group 3 p=0.01). The value of pCO2 was the highest in group 4 compared to groups 1, 2, and 3. The study found statistically significant differences in pH, pCO2 and pCO2 between group 4 (the group of dogs with bacterial peritonitis) and the other groups of dogs. This was probably linked to the pathogenesis of peritonitis. As a result of an inflammatory reaction within the peritoneal cavity, there is an increase in fibrin accumulations leading to a decreased oxygen supply causing the oxidative glucose metabolism to change into a non-oxidative glucose metabolism. This, in turn, causes a decrease in pH, acidosis, and a low oxidoreduction potential. It also impairs phagocytosis and activates proteolytic enzymes which create ideal conditions for the growth of anaerobic bacteria. The obtained results indicate that the pH, pO2 and pCO2 may be used to differentiate bacterial peritonitis from ascites of other etiologies.

Download full-text PDF

Source
http://dx.doi.org/10.1515/pjvs-2016-0018DOI Listing

Publication Analysis

Top Keywords

po2 pco2
16
group dogs
16
group
14
peritoneal fluid
12
bacterial peritonitis
12
group p=001
12
dogs
9
pco2 peritoneal
8
ascites etiologies
8
assess po2
8

Similar Publications

Introduction Chronic obstructive pulmonary disease (COPD) is a significant contributor to global morbidity and mortality. Despite well-established management protocols, treatment remains suboptimal due to high costs and mortality rates. This study aims to compare the impact of initial oxygenation status, Dyspnea, Eosinopenia, Consolidation, Acidemia, and Atrial Fibrillation (DECAF), and National Early Warning Score 2 (NEWS2) scores on management outcomes in COPD patients.

View Article and Find Full Text PDF

Automated tools for quantification of idiopathic pulmonary fibrosis (IPF) can aid in ensuring reproducibility, however their complexity and costs can differ substantially. In this retrospective study, two automated tools were compared in 45 patients with biopsy proven (12/45) and imaging-based (33/45) IPF diagnosis (mean age 74 ± 9 years, 37 male) for quantification of pulmonary fibrosis in CT. First, a tool that identifies multiple characteristic lung texture features was applied to measure multi-texture fibrotic lung (MTFL) by combining the amount of ground glass, reticulation, and honeycombing.

View Article and Find Full Text PDF

The tambaqui (Colossoma macropomum, G. Cuvier 1818) thrives both in the ion-poor waters of the Amazon and in commercial aquaculture. In both, environmental conditions can be harsh due to low ion levels, occasional high salt challenges (in aquaculture), low pH, extreme PO levels (hypoxia and hyperoxia), high PCO levels (hypercapnia), high ammonia levels (in aquaculture), and high and low temperatures.

View Article and Find Full Text PDF

Background Venous blood gas (VBG) investigation is a widespread option for arterial blood gas analysis because it is easier to draw and has a lower risk of complications during phlebotomy. This study aimed to establish reference intervals for the accurate analysis of VBG results as there is a lack of published data. Method Dr.

View Article and Find Full Text PDF

Background: Minimizing air aspiration by carefully filling blood gas syringes is crucial to prevent air contamination from causing undesirable variations in gasses and other molecules. While some previous studies investigated this aspect, these are now outdated and only analyzed a limited number of blood gas parameters. Thus, we investigated the effects air contamination in the syringe using a modern blood gas analyzer.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!