The impact of changes in influent load on the removal of endocrine disrupting chemicals (EDCs) by sewage treatment has not been fully characterised. This study assessed the efficacy of an advanced tertiary sewage treatment plant (STP) to remove EDCs during normal and peak flow events of sewage influent using trace chemical analysis of selected EDCs and four estrogenic in vitro bioassays. During the summer holiday season, influent volume increased by 68%, nutrient concentrations by at least 26% and hydraulic retention time was reduced by 40% compared with base flow conditions. Despite these pressures on the treatment system the concentrations and mass loading of estrone, 17β-estradiol, estriol, Bisphenol A, 4-t-octylphenol and technical nonylphenol were not significantly higher (p>0.05) during the peak flow conditions compared with base flow conditions. Chemical analysis and in vitro bioassays showed that the efficacy of the STP in removing EDCs was not affected by the different loadings between baseline and peak flow regimes. This study demonstrates that large flow variations within the design capacity of advanced multi-stage STPs should not reduce the removal efficacy of EDCs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.scitotenv.2016.04.003DOI Listing

Publication Analysis

Top Keywords

sewage treatment
12
peak flow
12
flow conditions
12
efficacy advanced
8
advanced tertiary
8
tertiary sewage
8
treatment plant
8
endocrine disrupting
8
disrupting chemicals
8
chemical analysis
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!