Biomechanical evaluation of laser-etched Ti implant surfaces vs. chemically modified SLA Ti implant surfaces: Removal torque and resonance frequency analysis in rabbit tibias.

J Mech Behav Biomed Mater

Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea. Electronic address:

Published: August 2016

Purpose: To compare osseointegration and implant stability of two types of laser-etched (LE) Ti implants with a chemically-modified, sandblasted, large-grit and acid-etched (SLA) Ti implant (SLActive(®), Straumann, Basel, Switzerland), by evaluating removal torque and resonance frequency between the implant surface and rabbit tibia bones. We used conventional LE Ti implants (conventional LE implant, CSM implant, Daegu, Korea) and LE Ti implants that had been chemically activated with 0.9% NaCl solution (LE active implant) for comparison with SLActive(®) implants

Materials And Methods: Two types of 3.3×8mm laser-etched Ti implants - conventional LE implants and LE active implants were prepared. LE implants and SLActive(®) implants were installed on the left and right tibias of 10 adult rabbits weighing approximately 3.0kg LE active implants and SLActive(®) implants were installed on the left and right tibias of 11 adult rabbits. After installation, we measured insertion torque (ITQ) and resonance frequency (ISQ). Three weeks (LE active) or 4 weeks (conventional LE) after installation, we measured removal torque (RTQ) and ISQ.

Results: In the conventional LE experiment, the mean ITQ was 16.99±6.35Ncm for conventional LE implants and 16.11±7.36Ncm for SLActive(®) implants (p=0.778>0.05). After 4 weeks, the mean of RTQ was 39.49±17.3Ncm for LE and 42.27±20.5Ncm for SLActive(®) (p=0.747>0.05). Right after insertion of the implants, the mean ISQ was 74.8±4.98 for conventional LE and 70.1±9.15 for SLActive(®) implants (p=0.169>0.05). After 4 weeks, the mean ISQ was 64.40±6.95 for LE and 67.70±9.83 for SLActive(®) (p=0.397>0.05). In the LE active experiment, the mean ITQ was 16.24±7.49Ncm for LE active implants and 14.33±5.06Ncm for SLActive(®) implants (p=0.491>0.05). After 3 weeks, the mean RTQ was 39.25±16.41Ncm for LE active and 41.56±10.41Ncm for SLActive(®) implants (p=0.698>0.05). Right after insertion of the implants, the mean ISQ was 58.64±10.51 for LE active implants and 53.82±15.36 for SLActive(®) implants (p=0.401>0.05). After 3 weeks, the mean ISQ was 63.82±5.88 for LE active and 66.27±6.53 for SLActive(®) (p=0.365>0.05).

Conclusion: We observed no significant differences in biomechanical bond strength to bone or implant stability in bone between the conventional LE Ti implant surface and the surface of the SLActive(®) implant or between the chemically activated LE Ti implant surface and the surface of the SLActive(®) implant during the early stage of osseointegration.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2016.03.034DOI Listing

Publication Analysis

Top Keywords

slactive® implants
28
implants
20
active implants
16
slactive®
14
implant
13
removal torque
12
resonance frequency
12
implant surface
12
conventional implants
12
active
9

Similar Publications

Objectives: Past studies have shown the efficacy of spinal targeted drug delivery (TDD) in pain relief, reduction in opioid use, and cost-effectiveness in long-term management of complex chronic pain. We conducted a survey to determine treatment variables associated with patient satisfaction.

Materials And Methods: Patients in a single pain clinic who were implanted with Medtronic pain pumps to relieve intractable pain were identified from our electronic health record.

View Article and Find Full Text PDF

Background: Mismatch between osteochondral allograft (OCA) donor and recipient sex has been shown to negatively affect outcomes. This study accounts for additional donor variables and clinically relevant outcomes.

Purpose: To evaluate whether donor sex, age, donor-recipient sex mismatch, and duration of graft storage affect clinical outcomes and failure rates after knee OCA transplantation.

View Article and Find Full Text PDF

Background: Knee injuries resulting in purely cartilaginous defects are rare, and controversy remains regarding the reliability of chondral-only fixation.

Purpose: To systematically review the literature for fixation methods and outcomes after primary fixation of chondral-only defects within the knee.

Study Design: Systematic review; Level of evidence, 5.

View Article and Find Full Text PDF

Comparative Analysis of Gelatin/Polylactic Acid and Commercial PLA Membranes for Guided Bone Regeneration: A Randomized Clinical Trial.

Med Sci Monit

January 2025

Department of Oral Implantology, The Affiliated Stomatology Hospital, Jiangxi Medical College, Nanchang University, Jiangxi Province Key Laboratory of Oral Biomedicine, Jiangxi Province Clinical Research Center for Oral Disease, Nanchang, Jiangxi, China.

BACKGROUND This study included 32 patients with single missing teeth and alveolar bone defects and aimed to compare outcomes from guided bone regeneration with a gelatin/polylactic acid (GT/PLA) barrier membrane and a Guidor® bioresorbable matrix barrier dental membrane. MATERIAL AND METHODS A total of 32 participants were recruited in the clinical study, with single missing teeth and alveolar bone defects, requiring guided bone regeneration (32 missing teeth in total). They were randomly divided into the GT/PLA membrane group (experimental) and Guidor® membrane group (control) by the envelope method (n=16).

View Article and Find Full Text PDF

Liver organoids have been increasingly adopted as a critical in vitro model to study liver development and diseases. However, the pre-vascularization of liver organoids without affecting liver parenchymal specification remains a long-lasting challenge, which is essential for their application in regenerative medicine. Here, the large-scale formation of pre-vascularized human hepatobiliary organoids (vhHBOs) is presented without affecting liver epithelial specification via a novel strategy, namely nonparenchymal cell grafting (NCG).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!