Objectives: To compare the diagnostic yield, complication rate, and procedure length of ultrasound fusion-guided liver biopsy to the diagnostic yield, complication rate, and procedure length of computed tomography (CT)-guided liver biopsy; to measure the average ionizing radiation dose that patients are exposed to during a typical CT-guided liver biopsy procedure; and to present relevant and interesting cases of ultrasound fusion-guided abdominal interventions to describe the efficacious use of the technology.

Methods: A retrospective analysis of 63 patients who had image-guided liver biopsies performed at our institution was completed. Patient records were divided into 2 groups according to the type of image guidance used during the procedure (ultrasound fusion versus CT), and data were compared by the χ(2) test, Student t test, and Mann-Whitney U test.

Results: The diagnostic yields and complication rates were not statistically significantly different between the modalities. The average procedure durations were significantly different: ultrasound fusion-guided biopsy, 31.63 minutes; compared to CT-guided biopsy, 61.67 minutes (P = .003).

Conclusions: Diagnostic yields and complication rates were comparable for ultrasound fusion and CT. However, the average procedure duration for an ultrasound fusion-guided liver biopsy was approximately half that of CT-guided liver biopsy, likely increasing both cost-effectiveness and patient satisfaction.

Download full-text PDF

Source
http://dx.doi.org/10.7863/ultra.15.06007DOI Listing

Publication Analysis

Top Keywords

liver biopsy
20
ultrasound fusion-guided
16
ultrasound fusion
12
ct-guided liver
12
computed tomography
8
diagnostic yield
8
yield complication
8
complication rate
8
rate procedure
8
procedure length
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!